• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§505-01 Apartment and Guest Room Identification and Directional Markings and Signs.

Title 3 ‒ Fire Department > 5 Fire Operations Features > §505-01 Apartment and Guest Room Identification and Directional Markings and Signs.
JUMP TO FULL CODE CHAPTER
   (a)   Scope. This section sets forth standards and requirements for the design and placement of entrance door room number markings for dwelling units (apartments, guest rooms and sleeping rooms) in Group R-1 and Group R-2 buildings and occupancies, and lobby and hallway corridor directional signs, which serve to assist emergency response personnel in locating such dwelling units.
   (b)   General Provisions.
      (1)   Applicability. The marking and sign provisions of FC505.3 and this section are operational and maintenance requirements. Pursuant to FC102.2, these requirements are applicable to all Group R-1 and Group R-2 buildings and occupancies subject to FC505.3, regardless of when such building or occupancy was constructed or established.
      (2)   Time for compliance. Pursuant to FC505.3.3, buildings and occupancies existing on May 31, 2016, shall be brought into compliance with the marking and sign requirements of FC505.3 and this section by March 30, 2017. Buildings and occupancies for which a certificate of occupancy or temporary certificate of occupancy is issued by the Department of Buildings on or after June 1, 2016, shall be compliant with such requirements prior to occupancy of the building or occupancy.
      (3)   Existing markings and signs. Any building or occupancy that has installed markings and signs prior to June 1, 2016, that vary from the requirements of FC505.3 and this section may retain such markings and signs, provided that such existing markings and signs are conspicuously and durably printed or posted, and communicate the same or substantially similar information required by this section. Any such existing marking or sign shall be replaced with a marking or sign that complies with the requirements of this section whenever the existing marking or sign in the building or occupancy is repainted or replaced.
      (4)   Conformance with plans. Entrance door room number and directional markings and signs must be consistent with the room numbers reflected upon any emergency preparedness plan or other plan requiring room identification prepared and/or filed in accordance with applicable laws, rules and regulations.
      (5)   Tampering. Pursuant to FC107.4.2, it is unlawful for any person to remove, deface, obscure or otherwise render illegible any marking or sign required by FC505.3 and this section.
   (c)   Dwelling Unit Entrance Door Identification.
      (1)   Where required. Pursuant to FC505.3, at least one (1) entrance door to each dwelling unit shall be marked or have a sign identifying the room number and/or letter as set forth in this section. Dwelling units having more than one (1) entrance door shall place the marking or sign on or adjacent to the main entrance door.
      (2)   Location. Pursuant to FC505.3, the entrance door marking or sign identifying the room number and/or letter shall be conspicuously and durably printed or posted on or adjacent to the entrance door, on the public corridor side of the door. The marking or sign letters and numbers shall be at least 48 inches, but not more than 60 inches, above the floor.
      (3)   Design. The entrance door markings and signs shall comply with the following design requirements:
         (A)   Letters and numbers shall be san serif, not less than one-half (1/2) inch in height, and shall use Arabic numerals and/or English alphabet capital letters.
         (B)   Character proportions and spacing, including stroke width, spacing between characters and line spacing, shall be in accordance with national and industry standards for building signage.
         (C)   Letters and numbers shall contrast with the background (whether of the door, the wall, or the sign) so as to be plainly discernible. Room number markings and signs may, but are not required to, include hyphens or other forms of punctuation.
         (4)   Method of affixing. Room number markings and signs shall be durably affixed in compliance with the following requirements:
            (A)   Painted markings shall be selected and applied in accordance with the manufacturer's instructions.
            (B)   Adhesives used to affix room number signs shall be sufficiently durable to ensure an extended useful life of the sign.
            (C)   Signs affixed to fire doors or fire-rated walls using screws or nails shall not compromise the fire rating of the door or wall.
   (d)   Building Lobby and Hallway Corridor Directional Markings or Signs.
      (1)   Where required. Pursuant to FC505.3, in a Group R-1 and Group R-2 building or occupancy with more than eight (8) dwelling units on a floor, a marking shall be placed or a sign posted in a conspicuous location in the elevator lobby or other public entry on each floor, and in the public corridor opposite each stairwell entrance, in accordance with R505-01(d)(2). The marking or sign shall identify by directional arrows and dwelling unit numbers and/or letters, the direction to each dwelling unit. Such markings or signs are not required in the public entry or opposite any stairwell entrance in any building or on any floor where the entrances to dwelling units are located in a single direction from such entry or stairwell entrance. For purposes of this section, a "single direction" means that all dwelling units are located along a single corridor. If dwelling units are located on more than one corridor, directional markings or signs shall be provided at each location where the corridor from the stairwell intersects with another corridor.
      (2)   Location. Pursuant to FC505.3, the directional markings and signs shall be conspicuously and durably printed or posted. The numbers, letters and directional arrows shall be at least 48 inches, but not more than 60 inches, above the floor. Stairwell directional markings or signs shall be located on the wall directly opposite the stairway entrance door. If there is no wall opposite such stairway entrance, or such location is not suitable for such purpose, the directional marking or sign shall be located at the nearest suitable location on the wall opposite the non-hinged side of the stairway entrance door.
      (3)   Design. The design of directional markings and signs shall be in accordance with R505-01(c)(3).
      (4)   Method of affixing. Directional markings and signs shall be affixed in accordance with R505-01(c)(4).
   (e)   Operational and Maintenance Requirements.
      (1)   Maintenance required. Markings and signs required by FC505.3 and this section shall be maintained in good repair. Markings and signs that are found to be missing, defaced, obscured, illegible, damaged or loose shall be repaired or replaced.
      (2)   Initial compliance inspection. Owners of buildings and occupancies subject to FC505.3 shall have such buildings and occupancies inspected within the time for compliance set forth in R505-01(b)(2) to confirm that such building or occupancy's markings and signs conform to the requirements of this section.
      (3)   Periodic compliance inspection. Owners of buildings and occupancies subject to FC505.3 shall have such buildings and occupancies inspected at least once per year to verify that the markings and signs are in good repair, and repair or replace any markings that are not.
   (f)   Recordkeeping.
      (1)   Compliance inspections. Records of the inspections required by R505-01(e)(2) and (3) shall be maintained in accordance with FC107.7. Dated entries shall be made with respect to the floors or other areas of the building or occupancy that have been inspected, the printed name and signature of the person who performed the inspection, and the markings or signs that require repair or replacement. Dated entries shall be made when such markings or signs are repaired and/or replaced.
      (2)   Existing markings and signs. A written record shall be made prior to March 30, 2017, of existing markings and signs retained in accordance with R505-01(b)(3). Such record shall be maintained for so long as the existing markings and signs are retained.
(Eff. 6/1/2016)

Related Code Sections


Section H104 Outdoor Signs, Identification
Every outdoor advertising display sign hereafter erected, constructed or maintained, for which a permit is required, shall be marked in accordance ...
NYC Building Code 2008 > H Outdoor Signs > H104 Identification
Section H104 Outdoor Signs, Identification
Every outdoor advertising display sign hereafter erected, constructed or maintained, for which a permit is required, shall be marked and identified ...
NYC Building Code 2014 > H Outdoor Signs > H104 Identification
H114.2.3 Outdoor Signs, Identification
The licensed sign hanger shall affix a decal bearing the UL Classification Mark or name of the testing entity and its listing number, and the date ...
NYC Building Code 2008 > H Outdoor Signs > H114 Flexible Fabric Signs > H114.2 Materials > H114.2.3 Identification
H114.2.3 Outdoor Signs, Identification
: All signs shall bear a decal bearing the UL classification mark or name of the testing entity and its ...
NYC Building Code 2014 > H Outdoor Signs > H114 Flexible Fabric Signs > H114.2 Materials > H114.2.3 Identification
703.6 Fire and Smoke Protection Features, Marking and Identification
shall be effectively and permanently identified with signs or stenciling. Such identification shall be located in accessible concealed floor, floor ...
NYC Building Code 2014 > 7 Fire and Smoke Protection Features > 703 Fire-Resistance Ratings and Fire Tests > 703.6 Marking and Identification
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE