• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.1441(d)(2) Anti Two-Blocking

OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1441 Equipment With a Rated Hoisting/Lifting Capacity of 2,000 Pounds or Less > 1926.1441(d) Safety Devices and Operational Aids > 1926.1441(d)(2) Anti Two-Blocking
JUMP TO FULL CODE CHAPTER
The employer must ensure that equipment covered by this section manufactured more than one year after November 8, 2010 have either an anti two-block device that meets the requirements of § 1926.1416(d)(3), or is designed so that, in the event of a two-block situation, no damage or load failure will occur (for example, by using a power unit that stalls in response to a two-block situation).

Related Code Sections


1926.1441(d)(2) Cranes & Derricks in Construction, Anti Two-Blocking
The employer must ensure that equipment covered by this section manufactured more than one year after November 8, 2010 have either an anti two-block ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1441 Equipment With a Rated Hoisting/Lifting Capacity of 2,000 Pounds or Less > 1926.1441(d) Safety Devices and Operational Aids > 1926.1441(d)(2) Anti Two-Blocking
1926.1431(d)(5)(v) Cranes & Derricks in Construction, Anti Two-Block
tip (or fixed upper block or similar component) must be used. The device(s) must prevent such damage/failure at all points where two-blocking could ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(d) Equipment Criteria > 1926.1431(d)(5) Devices > 1926.1431(d)(5)(v) Anti Two-Block
1926.1416(d)(3) Cranes & Derricks in Construction, Anti Two-Blocking Device
such damage at all points where two-blocking could occur. Temporary alternative measures: Clearly mark the cable (so that it can easily be seen ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1416 Operational Aids > 1926.1416(d) Category I Operational Aids and Alternative Measures > 1926.1416(d)(3) Anti Two-Blocking Device
1926.1435(e)(5)(iii) Cranes & Derricks in Construction, Anti Two-Blocking Device
component, and the boom tip (or fixed upper block or similar component). The device(s) must prevent such damage at all points where two-blocking could ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1435 Tower Cranes > 1926.1435(e) Operational Aids > 1926.1435(e)(5) Category I Operational Aids and Alternative Measures > 1926.1435(e)(5)(iii) Anti Two-Blocking Device
1926.1436(g)(2)(iv) Cranes & Derricks in Construction,
Actuating the anti two-block and boom hoist limit devices (if provided) ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1436 Derricks > 1926.1436(g) Post-Assembly Approval and Testing--New or Reinstalled Derricks > 1926.1436(g)(2) Functional Test > 1926.1436(g)(2)(iv)
Help Contact Us Privacy Terms
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE