Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

E 605.1.7.2.1 Annual Average Schedule

Uniform Mechanical Code 2018 of Nevada > E Sustainable Practices > E 605.0 Indoor Air Quality for Low-Rise Residential > E 605.1 General > E 605.1.7 Variable Mechanical Ventilation > E 605.1.7.2 Scheduled Ventilation > E 605.1.7.2.1 Annual Average Schedule
JUMP TO FULL CODE CHAPTER
An annual schedule of ventilation complies with this section when the annual average relative exposure during occupied periods is not more than unity as calculated in accordance with ASHRAE 62.2. [ASHRAE 62.2:4.5.2.1]

Related Code Sections


E 605.1.7.2.1 Sustainable Practices, Annual Average Schedule
An annual schedule of ventilation complies with this section when the annual average relative exposure during occupied periods is not more than unity ...
Uniform Mechanical Code 2018 of Nevada > E Sustainable Practices > E 605.0 Indoor Air Quality for Low-Rise Residential > E 605.1 General > E 605.1.7 Variable Mechanical Ventilation > E 605.1.7.2 Scheduled Ventilation > E 605.1.7.2.1 Annual Average Schedule
G2.4.2 Normative Appendix G Performance Rating Method, Annual Energy Costs
The design energy cost and baseline energy cost shall be determined using either actual rates for purchased energy or state average energy prices ...
Energy Standard for Buildings Except Low-Rise Residential Buildings 2016 of Nevada > Normative Appendix G Performance Rating Method > G2 Simulation General Requirements > G2.4 Renewable, Recovered, and Purchased Energy > G2.4.2 Annual Energy Costs
E 605.1.3.2 Sustainable Practices, Effective Annual Average Infiltration Rate (Qinf)
Effective Annual Average Infiltration Rate (Qinf) shall be calculated using Equation E 605.1.3.2: Qinf(cfm) = (NL × wsf × Afloor) / (7.3)*[Equation ...
Uniform Mechanical Code 2018 of Nevada > E Sustainable Practices > E 605.0 Indoor Air Quality for Low-Rise Residential > E 605.1 General > E 605.1.3 Dwelling-Unit Ventilation > E 605.1.3.2 Effective Annual Average Infiltration Rate (Qinf)
C3.5.4 Normative Appendix C Methodology for Building Envelope Trade-Off Option in Section 5.6, Schedules
The schedule types listed in Section C3.1.1(c) shall be required input. The schedules shall be consistent with those in the building envelope trade ...
Energy Standard for Buildings Except Low-Rise Residential Buildings 2016 of Nevada > Normative Appendix C Methodology for Building Envelope Trade-Off Option in Section 5.6 > C3 Simulation General Requirements > C3.5 Calculation of Proposed Envelope Performance Factor > C3.5.4 Schedules
D 112.2 Fuel Supply: Manufactured/Mobile Home Parks and Recreational Vehicle Parks, Minimum Oil Supply Tank Size
Oil supply tanks shall have a minimum capacity equal to 20 percent of the average annual oil consumption. [NFPA 501A:4.3.10] ...
Uniform Mechanical Code 2018 of Nevada > D Fuel Supply: Manufactured/Mobile Home Parks and Recreational Vehicle Parks > D 112.0 Oil Supply > D 112.2 Minimum Oil Supply Tank Size
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING