• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2122.7 Anchorage Requirements

2017 FBC - Building, 6th edition > 21 Masonry > 2122 High-Velocity Hurricane Zones— Reinforced Unit Masonry > 2122.7 Anchorage Requirements
JUMP TO FULL CODE CHAPTER
Anchorage shall be in accordance with TMS 402/ACI 530/ASCE 5. Loading shall comply with TMS 402/ACI 530/ASCE 5 Section 4.1 and the following.

2122.7.1

Reinforced masonry walls shall be securely anchored to adjacent structural members such as roofs, floors, columns, pilasters, buttresses and intersection walls.

2122.7.2

Masonry walls shall be anchored to all floors and roofs that provide lateral support to such walls.

2122.7.3

Such anchorage shall provide a positive direct connection capable of resisting the horizontal forces as required in Chapter 16 (High-Velocity Hurricane Zones), or a minimum force of 200 pounds per lineal foot (2919 N/m) of wall, whichever is greater.

2122.7.4

Required anchors shall be embedded in reinforced grouted cells. Anchor bolts shall be installed in accordance with TMS 602/ACI 530.1/ASCE 6 Section 3.4 D.

2122.7.5

Wood framing connected by nails shall not be considered as acceptable anchorage.

Related Code Sections


2122.7 Masonry, Anchorage Requirements
Anchorage shall be in accordance with TMS 402/ACI 530/ASCE 5. Loading shall comply with TMS 402/ACI 530/ASCE 5 Section 1.7 and the following ...
2014 FBC - Building, 5th edition > 21 Masonry > 2122 High-Velocity Hurricane Zones— Reinforced Unit Masonry > 2122.7 Anchorage Requirements
2122.7 Masonry, Anchorage Requirements
Anchorage shall be in accordance with TMS 402/ACI 530/ASCE 5. Loading shall comply with TMS 402/ACI 530/ASCE 5 Section 4.1 and the following ...
2017 FBC - Building, 6th edition > 21 Masonry > 2122 High-Velocity Hurricane Zones— Reinforced Unit Masonry > 2122.7 Anchorage Requirements
2122.7 Masonry, Anchorage Requirements
Anchorage shall be in accordance with TMS 402. Loading shall comply with TMS 402 Section 4.1 and the following ...
2020 FBC - Building, 7th edition > 21 Masonry > 2113 Masonry Chimneys > 2122 High-Velocity Hurricane Zones— Reinforced Unit Masonry > 2122.7 Anchorage Requirements
2122.7.4 Masonry,
Required anchors shall be embedded in reinforced grouted cells. Anchor bolts shall be installed in accordance with TMS 602/ACI 530.1/ASCE 6 Section ...
2014 FBC - Building, 5th edition > 21 Masonry > 2122 High-Velocity Hurricane Zones— Reinforced Unit Masonry > 2122.7 Anchorage Requirements > 2122.7.4
2122.7.1 Masonry,
Reinforced masonry walls shall be securely anchored to adjacent structural members such as roofs, floors, columns, pilasters, buttresses ...
2017 FBC - Building, 6th edition > 21 Masonry > 2122 High-Velocity Hurricane Zones— Reinforced Unit Masonry > 2122.7 Anchorage Requirements > 2122.7.1
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE