[BS] 503.10 Anchorage of Unreinforced Masonry Partitions in Major Alterations
Go To Full Code Chapter
Where the work area exceeds 50 percent of the building area, and where the building is assigned to Seismic Design Category C, D, E or F, unreinforced masonry partitions and nonstructural walls within the work area and adjacent to egress paths from the work area shall be anchored, removed or altered to resist out-of-plane seismic forces, unless an evaluation demonstrates compliance of such items. Use of reduced seismic forces shall be permitted.
Related Code Sections
503.10 Prescriptive Compliance Method, Anchorage of Unreinforced Masonry Partitions in Major Alterations
masonry partitions and nonstructural walls within the work area and adjacent to egress paths from the work area shall be anchored, removed or altered ...
503.10 Prescriptive Compliance Method, Anchorage of Unreinforced Masonry Partitions in Major Alterations
masonry partitions and nonstructural walls within the work area and adjacent to egress paths from the work area shall be anchored, removed or altered ...
906.7 Alterations—Level 3, Anchorage of Unreinforced Masonry Partitions
Where the building is assigned to Seismic Design Category C, D, E or F, unreinforced masonry partitions and nonstructural walls within the work area ...
906.7 Alterations—Level 3, Anchorage of Unreinforced Masonry Partitions
Where the building is assigned to Seismic Design Category C, D, E or F, unreinforced masonry partitions and nonstructural walls within the work area ...
906.4 Alterations—Level 3, Anchorage for Concrete and Masonry Buildings
of unreinforced masonry buildings unless an evaluation demonstrates compliance of existing wall anchorage. Reduced seismic forces shall be permitted ...