• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[BS] 906.5 Anchorage for Unreinforced Masonry Walls

2020 Existing Building Code of NYS > 9 Alterations — Level 3 > 906 Structural > 906.5 Anchorage for Unreinforced Masonry Walls
JUMP TO FULL CODE CHAPTER
For any building assigned to Seismic Design Category C, D, E or F with a structural system that includes unreinforced masonry bearing walls, the alteration work shall include installation of wall anchors at the roof line, unless an evaluation demonstrates compliance of existing wall anchorage. Reduced seismic forces shall be permitted.

Related Code Sections


906.5 Alterations — Level 3, Anchorage for Unreinforced Masonry Walls
For any building assigned to Seismic Design Category C, D, E or F with a structural system that includes unreinforced masonry bearing walls ...
2020 Existing Building Code of NYS > 9 Alterations — Level 3 > 906 Structural > 906.5 Anchorage for Unreinforced Masonry Walls
503.8 Prescriptive Compliance Method, Anchorage for Unreinforced Masonry Walls in Major Alterations
structural system includes unreinforced masonry bearing walls, the alteration work shall include installation of wall anchors at the floor and roof ...
2020 Existing Building Code of NYS > 5 Prescriptive Compliance Method > 503 Alterations > 503.8 Anchorage for Unreinforced Masonry Walls in Major Alterations
403.6 Prescriptive Compliance Method, Wall Anchorage for Unreinforced Masonry Walls in Major Alterations
is assigned to Seismic Design Category C, D, E or F, and the building's structural system includes unreinforced masonry walls, the alteration work shall ...
Existing Building Code 2015 of New York State > 4 Prescriptive Compliance Method > 403 Alterations > 403.6 Wall Anchorage for Unreinforced Masonry Walls in Major Alterations
A113.1.3 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings, Minimum Wall Anchorage
Anchorage of masonry walls to each floor or roof shall resist a minimum force determined as 0.9 S DS times the tributary weight or 200 pounds per ...
Existing Building Code 2015 of New York State > A1 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings > A113 Detailed System Design Requirements > A113.1 Wall Anchorage > A113.1.3 Minimum Wall Anchorage
A113.1.3 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings, Minimum Wall Anchorage
Anchorage of masonry walls to each floor or roof shall resist a minimum force determined as 0.9 S DS times the tributary weight or 200 pounds per ...
2010 Existing Building Code of NY > A1 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings > A113 Detailed System Design Requirements > A113.1 Wall Anchorage > A113.1.3 Minimum Wall Anchorage
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE