510.4.2.1 Amplification Systems and Components
JUMP TO FULL CODE CHAPTER
Buildings and structures that cannot support the required level of radio coverage shall be equipped with systems and components to enhance the public safety radio signals and achieve the required level of radio coverage specified in Sections 510.4.1 through 510.4.1.3. Public safety communications enhancement systems utilizing radio-frequency-emitting devices and cabling shall be approved by the fire code official. Prior to installation, all RF-emitting devices shall have the certification of the radio licensing authority and be suitable for public safety use.
Related Code Sections
510.4.2.1 Fire Service Features, Amplification Systems and Components
Buildings and structures that cannot support the required level of radio coverage shall be equipped with systems and components to enhance the public ...
California Fire Code 2019 > 5 Fire Service Features > 510 Emergency Responder Radio Coverage > 510.4 Technical Requirements > 510.4.2 System Design > 510.4.2.1 Amplification Systems and Components
510.4.2.1 Fire Service Features, Amplification Systems Allowed
Buildings and structures that cannot support the required level of radio coverage shall be equipped with a radiating cable system, a distributed ...
California Fire Code 2016 > 5 Fire Service Features > 510 Emergency Responder Radio Coverage > 510.4 Technical Requirements > 510.4.2 System Design > 510.4.2.1 Amplification Systems Allowed
3104F.2.3.3 [SLC] Marine Oil Terminals, Linear Modal Demand Procedure
displacement demands, to compute displacement components of an element along each axis of the system.
Sufficient modes shall be included ...
California Building Code 2016 (Vol 1 & 2) > 31F [SLC] Marine Oil Terminals > 3104F Seismic Analysis and Structural Performance > 3104F.2 Existing MOTs > 3104F.2.3 Analytical Procedures > 3104F.2.3.3 Linear Modal Demand Procedure
3103F.4.2.4 [SLC] Marine Oil Terminals, Simplified Evaluation of Site Amplification Effects
When the MOT site class is different from the Site Classes B to C boundary, site amplification effects shall be incorporated in peak ground ...
California Building Code 2016 (Vol 1 & 2) > 31F [SLC] Marine Oil Terminals > 3103F Structural Loading Criteria > 3103F.4 Earthquake Loads > 3103F.4.2 Design Earthquake Motion Parameters > 3103F.4.2.4 Simplified Evaluation of Site Amplification Effects
3103F.4.2.5 [SLC] Marine Oil Terminals, Site-Specific Evaluation of Amplification Effects
As an alternative to the procedure presented in Section 3103F.4.2.4, a site-specific response analysis may be performed. For Site Class F a site ...
California Building Code 2016 (Vol 1 & 2) > 31F [SLC] Marine Oil Terminals > 3103F Structural Loading Criteria > 3103F.4 Earthquake Loads > 3103F.4.2 Design Earthquake Motion Parameters > 3103F.4.2.5 Site-Specific Evaluation of Amplification Effects