604.8.2 Ambulatory Accessible Compartments
JUMP TO FULL CODE CHAPTER
Ambulatory accessible compartments shall comply with 604.8.2.
Ambulatory accessible compartments shall have a depth of 60 inches (1525 mm) minimum and a width of 35 inches (890 mm) minimum and 37 inches (940 mm) maximum.
Toilet compartment doors, including door hardware, shall comply with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the compartment and any obstruction shall be 42 inches (1065 mm) minimum. The door shall be self-closing. A door pull complying with 404.2.7 shall be placed on both sides of the door near the latch. Toilet compartment doors shall not swing into the minimum required compartment area.
Grab bars shall comply with 609. A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment.
Related Code Sections
604.8.2 Plumbing Elements and Facilities, Ambulatory Accessible Compartments
Ambulatory accessible compartments shall comply with 604.8.2 ...
2010 ADA Standards > 6 Plumbing Elements and Facilities > 604 Water Closets and Toilet Compartments > 604.8 Toilet Compartments > 604.8.2 Ambulatory Accessible Compartments
604.6 Plumbing Elements and Facilities, Flush Controls
on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2. Advisory 604.6 Flush Controls. If ...
2010 ADA Standards > 6 Plumbing Elements and Facilities > 604 Water Closets and Toilet Compartments > 604.6 Flush Controls
604.9.1 Plumbing Elements and Facilities, Location
and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in 604.8.2. Compartments ...
2010 ADA Standards > 6 Plumbing Elements and Facilities > 604 Water Closets and Toilet Compartments > 604.9 Water Closets and Toilet Compartments for Children's Use > 604.9.1 Location
604.2 Plumbing Elements and Facilities, Location
and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in 604.8.2. Water closets ...
2010 ADA Standards > 6 Plumbing Elements and Facilities > 604 Water Closets and Toilet Compartments > 604.2 Location
604 Plumbing Elements and Facilities, Water Closets and Toilet Compartments
inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in 604.8.2. Water closets shall ...