1107.5.5 Aluminum Tube
JUMP TO FULL CODE CHAPTER
Type 3003-0 aluminum tubing with high-pressure fittings shall not be used with methyl chloride and other refrigerants known to attack aluminum.
Related Code Sections
1107.5.5 Refrigeration, Aluminum Tube
Type 3003-0 aluminum tubing with high-pressure fittings shall not be used with methyl chloride and other refrigerants known to attack aluminum ...
Mechanical Code 2015 of Utah > 11 Refrigeration > 1107 Refrigerant Piping > 1107.5 Materials for Refrigerant Pipe and Tubing > 1107.5.5 Aluminum Tube
1107.5.5 Refrigeration, Aluminum Tube
Type 3003-0 aluminum tubing with high-pressure fittings shall not be used with methyl chloride and other refrigerants known to attack aluminum ...
Mechanical Code 2018 of Utah > 11 Refrigeration > 1107 Refrigerant Piping > 1107.5 Materials for Refrigerant Pipe and Tubing > 1107.5.5 Aluminum Tube
403.5.3 Gas Piping Installations, Aluminum Tubing
Aluminum-alloy tubing shall comply with ASTM B 210 or ASTM B 241. Aluminumalloy tubing shall be coated to protect against external corrosion where ...
Fuel Gas Code 2015 of Utah > 4 Gas Piping Installations > 403 (IFGS) Piping Materials > 403.5 Metallic Tubing > 403.5.3 Aluminum Tubing
403.5.4 Gas Piping Installations, Aluminum Tubing
Aluminum-alloy tubing shall comply with ASTM B210 or ASTM B241. Aluminumalloy tubing shall be coated to protect against external corrosion where ...
Fuel Gas Code 2018 of Utah > 4 Gas Piping Installations > 403 (IFGS) Piping Materials > 403.5 Metallic Tubing > 403.5.4 Aluminum Tubing
M2202.1 Special Piping and Storage Systems, Materials
Piping shall consist of steel pipe, copper and copper alloy pipe and tubing or steel tubing conforming to ASTM A 539. Aluminum tubing shall ...
Residential Code 2015 of Utah > 22 Special Piping and Storage Systems > M2202 Oil Piping, Fitting and Connections > M2202.1 Materials