The provisions of Section 1613.4 shall be permitted as alternatives to the relevant provisions of ASCE 7.
1613.4.1 Additional Seismic Force-Resisting Systems for Seismically Isolated Structures
Add the following exception to the end of Section 17.5.4.2 of ASCE 7:
Exception: For isolated structures designed in accordance with this standard, the structural system limitations including structural height limits, in Table 12.2-1 for ordinary steel concentrically braced frames (OCBFs) as defined in Chapter 11 and ordinary moment frames (OMFs) as defined in Chapter 11 are permitted to be taken as 160 feet (48 768 mm) for structures assigned to Seismic Design Category D, E or F, provided that the following conditions are satisfied:
  1. The value of RI as defined in Chapter 17 is taken as 1.
  2. For OMFs and OCBFs, design is in accordance with AISC 341.

Related Code Sections

1613.4 Structural Design, Alternatives to ASCE 7
The provisions of Section 1613.4 shall be permitted as alternatives to the relevant provisions of ASCE 7 ...
1613.6 Structural Design, Alternatives to ASCE 7
The provisions of Section 1613.6 shall be permitted as alternatives to the relevant provisions of ASCE 7 ...
1613.6.5 Structural Design, Seismic Controls for Elevators
Seismic switches in accordance with Section 8.4.10 of ASME A17.1 shall be deemed to comply with Section 13.6.10.3 of ASCE 7 ...
1613.6.6 Structural Design, Steel Plate Shear Wall Height Limits
Modify Section 12.2.5.4 of ASCE 7 to read as follows: 12.2.5.4 Increased building height limit for steel- braced frames, special steel plate ...
1613.6.7 Structural Design, Minimum Distance for Building Separation
16-44. (Equation 16-44) where: Cd = Deflection amplification factor in Table 12.2-1 of ASCE 7. max = Maximum displacement defined in Section ...