[BS] A301.3 Alternative Design Procedures
JUMP TO FULL CODE CHAPTER
The details and prescriptive provisions herein are not intended to be the only acceptable strengthening methods permitted. Alternative details and methods shall be permitted to be used where approved by the code official. Approval of alternatives shall be based on a demonstration that the method or material used is at least equivalent in terms of strength, deflection and capacity to that provided by the prescriptive methods and materials.
Where analysis by a registered design professional is required, such analysis shall be in accordance with all requirements of the building code, except that the seismic forces may be taken as 75 percent of those specified in the building code.
Related Code Sections
A301.3 Guidelines for the Seismic Retrofit of Existing Buildings, Alternative Design Procedures
The details and prescriptive provisions herein are not intended to be the only acceptable strengthening methods permitted. Alternative details ...
Los Angeles Existing Building Code > A Guidelines for the Seismic Retrofit of Existing Buildings > A301 General > A301.3 Alternative Design Procedures
A301.3 Prescriptive Provisions for Seismic Strengthening of Cripple Walls and Sill Plate Anchorage of Light, Wood-Frame Residential Buildings, Alternative Design Procedures
The details and prescriptive provisions herein are not intended to be the only acceptable strengthening methods permitted. Alternative details ...
Los Angeles Existing Building Code > A3 Prescriptive Provisions for Seismic Strengthening of Cripple Walls and Sill Plate Anchorage of Light, Wood-Frame Residential Buildings > A301 General > A301.3 Alternative Design Procedures
1613.3.5.2 Structural Design, Simplified Design Procedure
Where the alternate simplified design procedure of ASCE 7 is used, the seismic design category shall be determined in accordance with ASCE 7 ...
Los Angeles Building Code > 16 Structural Design > 1613 Earthquake Loads > 1613.3 Seismic Ground Motion Values > 1613.3.5 Determination of Seismic Design Category > 1613.3.5.2 Simplified Design Procedure
1609.6.4.1 Structural Design, Main Wind Force-Resisting Systems
The MWFRS shall be investigated for the torsional effects identified in ASCE 7 Figure 27.4-8 ...
Los Angeles Building Code > 16 Structural Design > 1609 Wind Loads > 1609.6 Alternate All-Heights Method > 1609.6.4 Design Procedure > 1609.6.4.1 Main Wind Force-Resisting Systems
1609A.6.4.1 Structural Design, Main Wind Force-Resisting Systems
The MWFRS shall be investigated for the torsional effects identified in ASCE 7 Figure 27.4-8 ...
Los Angeles Building Code > 16A Structural Design > 1609A Wind Loads > 1609A.6 Alternate All-Heights Method > 1609A.6.4 Design Procedure > 1609A.6.4.1 Main Wind Force-Resisting Systems