• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R404.1.3.3.7.6 Alternate Grade of Reinforcement and Spacing

Residential Code 2018 of Kansas > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.3 Concrete Foundation Walls > R404.1.3.3 Concrete, Materials for Concrete, and Forms > R404.1.3.3.7 Reinforcement > R404.1.3.3.7.6 Alternate Grade of Reinforcement and Spacing
JUMP TO FULL CODE CHAPTER
Where tables in Section R404.1.3.2 specify vertical wall reinforcement based on minimum bar size and maximum spacing, which are based on Grade 60 (414 MPa) steel reinforcement, different size bars or bars made from a different grade of steel are permitted provided that an equivalent area of steel per linear foot of wall is provided. Use of Table R404.1.2(9) is permitted to determine the maximum bar spacing for different bar sizes than specified in the tables or bars made from a different grade of steel. Bars shall not be spaced less than one-half the wall thickness, or more than 48 inches (1219 mm) on center.

Related Code Sections


R404.1.3.3.7.6 Foundations, Alternate Grade of Reinforcement and Spacing
Where tables in Section R404.1.3.2 specify vertical wall reinforcement based on minimum bar size and maximum spacing, which are based on Grade 60 ...
Residential Code 2018 of Kansas > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.3 Concrete Foundation Walls > R404.1.3.3 Concrete, Materials for Concrete, and Forms > R404.1.3.3.7 Reinforcement > R404.1.3.3.7.6 Alternate Grade of Reinforcement and Spacing
R608.5.4.7 Wall Construction, Alternate Grade of Reinforcement and Spacing
Where tables in Sections R404.1.3 and R608.6 specify vertical wall reinforcement based on minimum bar size and maximum spacing, which are based ...
Residential Code 2018 of Kansas > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.5 Materials > R608.5.4 Reinforcement Installation Details > R608.5.4.7 Alternate Grade of Reinforcement and Spacing
1807.1.6.3.1 Soils and Foundations, Alternative Foundation Wall Reinforcement
In lieu of the reinforcement provisions for masonry foundation walls in Table 1807.1.6.3(2), 1807.1.6.3(3) or 1807.1.6.3(4), alternative reinforcing ...
Building Code 2018 of Kansas > 18 Soils and Foundations > 1807 Foundation Walls, Retaining Walls and Embedded Posts and Poles > 1807.1 Foundation Walls > 1807.1.6 Prescriptive Design of Concrete and Masonry Foundation Walls > 1807.1.6.3 Masonry Foundation Walls > 1807.1.6.3.1 Alternative Foundation Wall Reinforcement
18.8.3 Earthquake-Resistant Structures, Transverse Reinforcement
be confined by transverse reinforcement passing through the column that satisfies spacing requirements of 18.6.4.4, and requirements of 18.6.4.2 ...
Building Code Requirements for Structural Concrete of Kansas > 18 Earthquake-Resistant Structures > 18.8 Joints of Special Moment Frames > 18.8.3 Transverse Reinforcement
25.7.2 Reinforcement Details, Ties
Ties shall consist of a closed loop of deformed bar with spacing in accordance with (a) and (b): (a) Clear spacing of at least (4/3) d agg (b ...
Building Code Requirements for Structural Concrete of Kansas > 25 Reinforcement Details > 25.7 Transverse Reinforcement > 25.7.2 Ties
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE