101.4.3.2 Alterations to Building Envelope
JUMP TO FULL CODE CHAPTER
New building envelope assemblies that are part of the alteration shall comply with Sections 101.4.3.2.1 and 101.4.3.2.2 or alternatively with ASHRAE 90.1-2010 as amended by Appendix A of this code.
The addition of vertical fenestration that results in a total building fenestration area less than or equal to that specified in Section C402.3.1 shall comply with Section C402.3. The addition of vertical fenestration that results in a total building fenestration area greater than Section C402.3.1 shall comply with Section C402.3.1.1 for the space adjacent to the new fenestration only. Alterations that result in a total building vertical glass area exceeding that specified in Section C402.3.1.1 shall comply with Section C407.
The addition of skylight area that results in a total building skylight area less than or equal to that specified in Section C402.3.1 shall comply with Section C402.3. The addition of skylight area that results in a total building skylight area greater than Section C402.3.1 shall comply with Section C402.3.1.2 for the space adjacent to the new skylights. Alterations that result in a total building skylight area exceeding that specified in Section C402.3.1.2 shall comply with Section C407.
Related Code Sections
§27-731 Light, Heat, Ventilation and Noise Control, Alterations
No building, or part thereof, shall hereafter be altered or rearranged so as to reduce any of the following to less than the required standards ...
NYC 1968 Code (Vol I) > 12 Light, Heat, Ventilation and Noise Control > 2 Existing Buildings > §27-731 Alterations
D103.2 Fire Districts, Other Alterations
Nothing in Section D103.1 shall prohibit other alterations within the fire district provided there is no change of occupancy that is otherwise ...
D103.2 Fire Districts, Other Alterations
Nothing in Section D103.1 shall prohibit other alterations within the fire district provided there is no change of occupancy that is otherwise ...
1704.22.1.4 Structural Tests and Special Inspections, Alterations
For alterations not covered under Sections 1704.22.1.2 or 1704.22.1.3 above, the permit holder shall perform a final acceptance test of the completed ...
NYC Building Code 2008 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.22 Standpipe System Special Inspection > 1704.22.1 Hydrostatic Pressure Testing > 1704.22.1.4 Alterations
1704.24.1.4 Structural Tests and Special Inspections, Alterations
For alterations not covered under Sections 1704.24.1.2 or 1704.24.1.3 above, the permit holder shall perform a final acceptance test of the completed ...
NYC Building Code 2014 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.24 Standpipe System Special Inspection > 1704.24.1 Hydrostatic Pressure Testing > 1704.24.1.4 Alterations