(a) Except as otherwise provided for in this section, if the alteration of a building or space therein results in a change in the occupancy group classification of the building under the provisions of subchapter three, then the entire building shall be made to comply with the requirements of this code.

(b) Except as otherwise provided for in this section, if the alteration of a space in a building involves a change in the occupancy or use thereof, the alteration work involved in the change shall, except as provided for in this section, be made to comply with the requirements of this code and the remaining portion of the building shall be altered to such an extent as may be necessary to protect the safety and welfare of the occupants.

(c) When, however, the cost of alterations involved in the change of occupancy of an existing building erected prior to December sixth, nineteen hundred sixty-eight or space therein authorizes the alterations to be made in compliance with the applicable laws in existence on such sixth day of December, nineteen hundred sixty-eight, such change in occupancy may similarly be made in compliance with such prior laws, provided the general safety and public welfare are not thereby endangered, and further provided that the alteration work shall effect compliance with all requirements of this code relating to interior finish work, finish flooring and floor covering, sprinklers, interior fire alarms, fire command and communication systems, elevators, smoke detectors, directional signs, emergency lighting and emergency power.
Upcodes Diagrams

Related Code Sections

§27-118 Administration and Enforcement, Alterations Involving Change in Occupancy or Use
of this code. (b) Except as otherwise provided for in this section, if the alteration of a space in a building involves a change in the occupancy or use ...
*§28-109.1 Administration, Fire Protection Plan Required for Covered Buildings
not involve a change of use or occupancy; The alteration does not exceed $1,000,000; and The alteration does not create an inconsistency ...
*§28-109.1 Administration, Fire Protection Plan Required for Covered Buildings
does not involve a change of use or occupancy; The alteration does not exceed one million dollars; and The alteration does not create ...
Article 20 Special Uses and Occupancies, Occupancies Involving Storage of Nitric Acid
This article shall apply to the construction, alteration and use of buildings or spaces wherein nitric acid is stored ...