1808.3.4 Allowable Uplift Load
JUMP TO FULL CODE CHAPTER
Where required by the design, the allowable uplift load for a single pile shall be determined in accordance with accepted engineering practices based on a minimum factor of safety of three or by uplift load tests performed in accordance with Section 1808.4.2.1. Where uplift load tests are performed, the maximum allowable uplift load shall not exceed the ultimate load capacity divided by a factor of safety of two. The allowable uplift load for a pile group shall not exceed the sum of the allowable uplift loads of the individual piles in the group, nor the uplift capacity calculating the group action of the pile in accordance with accepted engineering practice where the calculated ultimate group capacity is divided by a safety factor of 2.5.
Related Code Sections
1808.3.4 Soils and Foundations, Allowable Uplift Load
Where required by the design, the allowable uplift load for a single pile shall be determined in accordance with accepted engineering practices based ...
NYC Building Code 2014 > 18 Soils and Foundations > 1808 Deep Foundations > 1808.3 Allowable Pile Loads > 1808.3.4 Allowable Uplift Load
1808.2.8.5 Soils and Foundations, Uplift Capacity
on a minimum factor of safety of three or by uplift load tests conducted in accordance with ASTM D 3689. The maximum allowable uplift load shall ...
NYC Building Code 2008 > 18 Soils and Foundations > 1808 Pier and Pile Foundations > 1808.2 Piers and Piles—General Requirements > 1808.2.8 Allowable Pier or Pile Loads > 1808.2.8.5 Uplift Capacity
2305.3.6 Wood, Overturning Restraint
Where the dead load stabilizing moment in accordance with Chapter 16 allowable stress design load combinations is not sufficient to prevent uplift ...
NYC Building Code 2008 > 23 Wood > 2305 General Design Requirements for Lateral-Force-Resisting Systems > 2305.3 Design of Wood Shear Walls > 2305.3.6 Overturning Restraint
2308.10.1 Wood, Wind Uplift
and multiply by 0.5 for framing spaced 12 inches on center.
The uplift connection requirements include an allowance for 10 pounds of dead load.
The uplift ...
NYC Building Code 2008 > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.10 Roof and Ceiling Framing > 2308.10.1 Wind Uplift
2308.10.1 Wood, Wind Uplift
on center. c. The uplift connection requirements include an allowance for 10 pounds of dead load. d. The uplift connection requirements do ...
NYC Building Code 2014 > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.10 Roof and Ceiling Framing > 2308.10.1 Wind Uplift