• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

11.3.5 Allowable Shear Loads

California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 11 Evaluation of Critical Nonstructural Components and Systems > 11.3 Testing Requirements for Evaluating the Performance of Existing Mechanical Fasteners > 11.3.5 Allowable Shear Loads
JUMP TO FULL CODE CHAPTER

Allowable shear loads on anchors shall be determined by either of the following:

  1. Shear values listed in Table 19B-E of 1998 California Building Code (CBC) or equivalent provision in later version of the CBC, or
  2. Shear values shall be obtained by analysis using Strength Design of Anchorage to Concrete, Section A.6, published by the Portland Cement Association, 1999, with the specified reduction coefficient(s) to convert the "strength" values to allowable stress design values of 1.7.

Related Code Sections


11.3.5 Seismic Evaluation Procedures for Hospital Buildings, Allowable Shear Loads
Allowable shear loads on anchors shall be determined by either of the following: Shear values listed in Table 19B-E of 1998 California Building ...
California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 11 Evaluation of Critical Nonstructural Components and Systems > 11.3 Testing Requirements for Evaluating the Performance of Existing Mechanical Fasteners > 11.3.5 Allowable Shear Loads
11.3.5 Seismic Evaluation Procedures for Hospital Buildings, Allowable Shear Loads
Allowable shear loads on anchors shall be determined by either of the following: Shear values listed in Table 19B-E of 1998 California Building ...
California Administrative Code 2016 > 6 Seismic Evaluation Procedures for Hospital Buildings > 11 Evaluation of Critical Nonstructural Components and Systems > 11.3 Testing Requirements for Evaluating the Performance of Existing Mechanical Fasteners > 11.3.5 Allowable Shear Loads
1127A.4.4 Housing Accessibility, Structural Strength
in a grab bar or seat induced by the maximum bending moment from the application of a 250-pound (1112 N) point load shall be less than the allowable ...
California Building Code 2016 (Vol 1 & 2) > 11A Housing Accessibility > 1127A Common Use Facilities > 1127A.4 Grab Bars, Tub and Shower Seats, Fasteners and Mounting Devices > 1127A.4.4 Structural Strength
3107F.3.3.4 [SLC] Marine Oil Terminals, Shear Design
of pile For the seismic load combinations, the maximum allowable shear stress, τ capacity , is the design shear strength, τ design , from the ANSI/AWC ...
California Building Code 2016 (Vol 1 & 2) > 31F [SLC] Marine Oil Terminals > 3107F Structural Analysis and Design of Components > 3107F.3 Timber Piles and Deck Components > 3107F.3.3 Timber Piles > 3107F.3.3.4 Shear Design
A206.2 Guidelines for the Seismic Retrofit of Existing Buildings, Special Requirements for Wall Anchorage Systems
of existing shear anchors. Expansion anchors are only allowed with special inspection and approved testing for seismic loading. Attaching the edge ...
California Existing Building Code 2019 > A Guidelines for the Seismic Retrofit of Existing Buildings > A206 Analysis and Design > A206.2 Special Requirements for Wall Anchorage Systems
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE