• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R802.5 Allowable Rafter Spans

Residential Code 2012 of South Holland > 8 Roof-Ceiling Construction > R802 Wood Roof Framing > R802.5 Allowable Rafter Spans
JUMP TO FULL CODE CHAPTER
Spans for rafters shall be in accordance with Tables R802.5.1(1) through R802.5.1(8). For other grades and species and for other loading conditions, refer to the AF&PA; Span Tables for Joists and Rafters. The span of each rafter shall be measured along the horizontal projection of the rafter.
SEE MORE

Related Code Sections


R802.5 Roof-Ceiling Construction, Allowable Rafter Spans
Spans for rafters shall be in accordance with Tables R802.5.1(1) through R802.5.1(8). For other grades and species and for other loading conditions ...
Residential Code 2012 of South Holland > 8 Roof-Ceiling Construction > R802 Wood Roof Framing > R802.5 Allowable Rafter Spans
2308.7.7 Wood, Purlins
Purlins to support roof loads are permitted to be installed to reduce the span of rafters within allowable limits and shall be supported by struts ...
Building Code 2018 of South Holland > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.7 Roof and Ceiling Framing > 2308.7.7 Purlins
2308.10.5 Wood, Purlins
Purlins to support roof loads are permitted to be installed to reduce the span of rafters within allowable limits and shall be supported by struts ...
Building Code 2012 of South Holland > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.10 Roof and Ceiling Framing > 2308.10.5 Purlins
Chapter 8 Roof-Ceiling Construction
framing systems: wood framing and cold-formed steel framing. Allowable span tables are provided to simplify the selection of rafter and ceiling joist ...
Residential Code 2018 of South Holland > 8 Roof-Ceiling Construction
2306.1.1 Wood, Joists and Rafters
The design of rafter spans is permitted to be in accordance with the AF&PA Span Tables for Joists and Rafters ...
Building Code 2012 of South Holland > 23 Wood > 2306 Allowable Stress Design > 2306.1 Allowable Stress Design > 2306.1.1 Joists and Rafters
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING