Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

507.8.1 Allowable Area

2017 FBC - Building, 6th edition > 5 General Building Heights and Areas > 507 Unlimited Area Buildings > 507.8 Group H-2, H-3 and H-4 Occupancies > 507.8.1 Allowable Area
JUMP TO FULL CODE CHAPTER
The aggregate floor area of Group H occupancies located in an unlimited area building shall not exceed 10 percent of the area of the building or the area limitations for the Group H occupancies as specified in Section 506 based on the perimeter of each Group H floor area that fronts on a public way or open space.

507.8.1.1 Located Within the Building

The aggregate floor area of Group H occupancies not located at the perimeter of the building shall not exceed 25 percent of the area limitations for the Group H occupancies as specified in Section 506.

507.8.1.1.1 Liquid Use, Dispensing and Mixing Rooms

Liquid use, dispensing and mixing rooms having a floor area of not more than 500 square feet (46.5 m2) need not be located on the outer perimeter of the building where they are in accordance with the Florida Fire Prevention Code and NFPA 30.

507.8.1.1.2 Liquid Storage Rooms

Liquid storage rooms having a floor area of not more than 1,000 square feet (93 m2) need not be located on the outer perimeter where they are in accordance with the Florida Fire Prevention Code and NFPA 30.

507.8.1.1.3 Spray Paint Booths

Spray paint booths that comply with the Florida Fire Prevention Code need not be located on the outer perimeter.

Related Code Sections


507.8.1 General Building Heights and Areas, Allowable Area
The aggregate floor area of Group H occupancies located in an unlimited area building shall not exceed 10 percent of the area of the building nor ...
2014 FBC - Building, 5th edition > 5 General Building Heights and Areas > 507 Unlimited Area Buildings > 507.8 Group H Occupancies > 507.8.1 Allowable Area
507.8.1 General Building Heights and Areas, Allowable Area
The aggregate floor area of Group H occupancies located in an unlimited area building shall not exceed 10 percent of the area of the building ...
2017 FBC - Building, 6th edition > 5 General Building Heights and Areas > 507 Unlimited Area Buildings > 507.8 Group H-2, H-3 and H-4 Occupancies > 507.8.1 Allowable Area
507.8.1 General Building Heights and Areas, Allowable Area
The aggregate floor area of Group H occupancies located in an unlimited area building shall not exceed 10 percent of the area of the building ...
2020 FBC - Building, 7th edition > 5 General Building Heights and Areas > 507 Unlimited Area Buildings > 507.8 Group H-2, H-3 and H-4 Occupancies > 507.8.1 Allowable Area
1401.6.2.1 Performance Compliance Methods, Allowable Area Formula
The following formula shall be used in computing allowable area: A a = { A t + [ A t × I f ] + [ A t × I s ]} (Equation 14-3 ...
2014 FBC - Existing Building, 5th edition > 14 Performance Compliance Methods > 1401 General > 1401.6 Evaluation Process > 1401.6.2 Building Area > 1401.6.2.1 Allowable Area Formula
1401.6.2.1 Performance Compliance Methods, Allowable Area Formula
The following formula shall be used in computing allowable area: (Equation 14-3) where: A a = Allowable building area per story (square ...
2017 FBC - Existing Building, 6th edition > 14 Performance Compliance Methods > 1401 General > 1401.6 Evaluation Process > 1401.6.2 Building Area > 1401.6.2.1 Allowable Area Formula
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE