12.2.5.6.8 Aisle Landings
Go To Full Code Chapter
Where the path of travel on a stair, an aisle stair, or aisle ramp continues to another stair of different rise or tread depth, another aisle stair of different rise or tread depth, or another aisle ramp of different slope, there shall be a landing whose depth is equal to or greater than the width of the aisle stair or ramp, unless otherwise permitted by one of the following:
- No landing shall be required within aisle stairs with nonuniform risers, as permitted by 12.2.5.6.6(7).
- No landing shall be required between aisle ramps of different slopes.
- No landing shall be required between an aisle ramp and an aisle accessway or between an aisle stair and an aisle accessway.
- A minimum 30 in. (760 mm) deep landing shall be permitted between an aisle stair and a stair with the same tread depths or between an aisle stair and another aisle stair with the same tread depths.
- A minimum 30 in. (760 mm) deep landing shall be permitted between an aisle stair and a stair with greater tread depth in the descending direction and between an aisle stair and another aisle stair with greater tread depth in the descending direction.
- A minimum 30 in. (760 mm) deep landing shall be permitted between an aisle stair and a stair with less tread depth in the descending direction and between an aisle stair and another aisle stair with less tread depth in the descending direction.
- A minimum 22 in. (560 mm) deep landing shall be permitted between an aisle ramp and a stair and between an aisle ramp and an aisle stair.
- No landing depth shall be required to exceed 48 in. (1220 mm).
Related Code Sections
12.2.5.6.8 New Assembly Occupancies, Aisle Landings
of different rise or tread depth, or another aisle ramp of different slope, there shall be a landing whose depth is equal to or greater than the width ...
13.2.5.6.8 Existing Assembly Occupancies, Aisle Landings
of different rise or tread depth, or another aisle ramp of different slope, there shall be a landing whose depth is equal to or greater than the width ...
1029.13.1.2 Means of Egress, Landings
Ramped aisles shall have landings in accordance with Sections 1012.6 through 1012.6.5. Landings for ramped aisles shall be permitted to overlap ...
13.2.5.6.9* Existing Assembly Occupancies, Aisle Handrails
Where an aisle stair leading to the aisle transition stair is provided with a center handrail and the aisle landing is less than 48 ...