• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1104.22.1 Aisle and Aisle Accessway Width

Minnesota Fire Code 2015 > 11 Construction Requirements for Existing Buildings > 1104 Means of Egress for Existing Buildings > 1104.22 Minimum Aisle Width > 1104.22.1 Aisle and Aisle Accessway Width
JUMP TO FULL CODE CHAPTER
Aisles and aisle accessway widths shall be as determined by the occupant load calculations in Section 1005.3, but not less than the widths shown in Table 1104.22.

Related Code Sections


1104.22.1 Construction Requirements for Existing Buildings, Aisle and Aisle Accessway Width
Aisles and aisle accessway widths shall be as determined by the occupant load calculations in Section 1005.3, but not less than the widths shown ...
Minnesota Fire Code 2015 > 11 Construction Requirements for Existing Buildings > 1104 Means of Egress for Existing Buildings > 1104.22 Minimum Aisle Width > 1104.22.1 Aisle and Aisle Accessway Width
Section 1017 Means of Egress, Aisles
or counters are served by fixed seats, the width of the aisle or aisle accessway shall be measured from the back of the seat. Where seating ...
Minnesota Fire Code 2015 > 10 Means of Egress > 1017 Aisles
Section 1017 Means of Egress, Aisles
tables or counters are served by fixed seats, the width of the aisle or aisle accessway shall be measured from the back of the seat. Where seating ...
Minnesota Building Code 2015 > 10 Means of Egress > 1017 Aisles
1029.13 Means of Egress, Aisle Accessways
and is adjacent to an aisle or aisle accessway , the measurement of required clear width of the aisle or aisle accessway shall be made ...
2020 Minnesota Building Code > 10 Means of Egress > 1029 Assembly > 1029.13 Aisle Accessways
1028.10 Means of Egress, Aisle Accessways
and is adjacent to an aisle or aisle accessway , the measurement of required clear width of the aisle or aisle accessway shall be made ...
Minnesota Building Code 2015 > 10 Means of Egress > 1028 Assembly > 1028.10 Aisle Accessways
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE