Where the day-night average sound level (Ldn) is determined to be 65 dBA or greater, the minimum STC rating of structure components shall be provided in compliance with Table 1206.4. As an alternative to compliance with Table 1206.4, structures shall be permitted to be designed and constructed so as to limit the interior noise level to no greater than 45 Ldn. Exterior structures, terrain and permanent plantings shall be permitted to be included as part of the alternative design. The alternative design shall be certified by a registered design professional (RDP).
AIRPORT NOISE ATTENUATION STANDARDS
Ldn STC OF EXTERIOR WALLS AND ROOF/CEILING ASSEMBLIES STC OF DOORS AND WINDOWS
65 — 69 39 25
70 — 74 44 33
75 or greater 49 38
Upcodes Diagrams

Related Code Sections

1206.4 Interior Environment, Airport Noise Attenuation Standards
as part of the alternative design. The alternative design shall be certified by a registered design professional (RDP). TABLE 1206.4 AIRPORT NOISE ...
1207.4 Interior Environment, Airport Noise Attenuation Standards
design. The alternative design shall be certified by an RDP. TABLE 1207.4 AIRPORT NOISE ATTENUATION STANDARDS LDN STC OF EXTERIOR WALLS AND ROOF ...
1207.4 Interior Environment, Airport Noise Attenuation Standards
design. The alternative design shall be certified by an RDP. TABLE 1207.4 AIRPORT NOISE ATTENUATION STANDARDS LDN STC OF EXTERIOR ...
R327.2 Building Planning, Airport Noise Attenuation
dwellings (townhouses) not more than three stories high with separate means of egress within airport noise zones when enforced by a locality pursuant ...
R330.2 Building Planning, Airport Noise Attenuation
(townhouses) not more than three stories high with separate means of egress within airport noise zones when enforced by a locality pursuant to § 15.2-2295 ...