• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

42.10.3 Airport Fuel Systems

Fire Code 2015 of Delaware > 42 Refueling > 42.10 Aircraft Fuel Servicing > 42.10.3 Airport Fuel Systems
JUMP TO FULL CODE CHAPTER

42.10.3.1 Design Approval

Work shall not be started on the construction or alteration of an airport fuel system until the design, plans, and specifications have been approved by the AHJ. [407:4.4.1]

42.10.3.2 System Approval

The AHJ shall inspect and approve the completed system before it is put into service. [407:4.4.2]

42.10.3.3 Fuel Storage Tanks

42.10.3.3.1*

Fuel storage tanks shall conform to the applicable requirements of NFPA 30. [407:4.4.4.1]

42.10.3.3.2

The AHJ shall determine the clearances required from runways, taxiways, and other aircraft movement and servicing areas to any aboveground fuel storage structure or fuel transfer equipment, with due recognition given to national and international standards establishing clearances from obstructions. Tanks located in designated aircraft movement areas or aircraft servicing areas shall be underground or mounded over with earth. Vents from such tanks shall be constructed in a manner to preclude collision hazards with operating aircraft. Aircraft operators shall be consulted regarding the height and location of such vents to avoid venting flammable vapors in the vicinity of ignition sources, including operating aircraft and automotive equipment permitted in the area. [407:4.4.4.2]

Related Code Sections


42.10.3 Refueling, Airport Fuel Systems
Work shall not be started on the construction or alteration of an airport fuel system until the design, plans, and specifications have been approved ...
Fire Code 2015 of Delaware > 42 Refueling > 42.10 Aircraft Fuel Servicing > 42.10.3 Airport Fuel Systems
42.10.3.1.1 Refueling, General Requirements
as an integral part of the airport fuel system. [ 407: 5.1.1.3 ...
Fire Code 2021 of Delaware > 42 Refueling > 42.10 Aircraft Fuel Servicing > 42.10.3 Aviation Fueling Facilities > 42.10.3.1 Design and Construction > 42.10.3.1.1 General Requirements
42.10.3.1.1.3 Refueling,
The emergency fuel shutoff system shall be designed and installed as an integral part of the airport fuel system. [ 407: 5.1.1.3] ...
Fire Code 2021 of Delaware > 42 Refueling > 42.10 Aircraft Fuel Servicing > 42.10.3 Aviation Fueling Facilities > 42.10.3.1 Design and Construction > 42.10.3.1.1 General Requirements > 42.10.3.1.1.3
42.10.3.1.1.6 Refueling, System Design and Approval
Work shall not be started on the construction or alteration of an airport fuel system until the design, plans, and specifications have been approved ...
Fire Code 2021 of Delaware > 42 Refueling > 42.10 Aircraft Fuel Servicing > 42.10.3 Aviation Fueling Facilities > 42.10.3.1 Design and Construction > 42.10.3.1.1 General Requirements > 42.10.3.1.1.6 System Design and Approval
42.10.2.1.5.1 Refueling,
A provision for bonding shall be incorporated in the design of fuel servicing vehicles or carts and airport fueling systems to prevent differences ...
Fire Code 2021 of Delaware > 42 Refueling > 42.10 Aircraft Fuel Servicing > 42.10.2 General Requirements > 42.10.2.1 Design and Construction > 42.10.2.1.5 Electrostatic Hazards and Bonding > 42.10.2.1.5.1
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING