• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

412.7 Aircraft Manufacturing Facilities

Building Code 2015 of Utah > 4 Special Detailed Requirements Based on Use and Occupancy > 412 Aircraft-Related Occupancies > 412.7 Aircraft Manufacturing Facilities
JUMP TO FULL CODE CHAPTER
In buildings used for the manufacturing of aircraft, exit access travel distances indicated in Section 1017.1 shall be increased in accordance with the following:
  1. The building shall be of Type I or II construction.
  2. Exit access travel distance shall not exceed the distances given in Table 412.7.
TABLE 412.7
AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE
HEIGHT (feet) b MANUFACTURING AREA (sq. ft.) a
≥ 150,000 ≥ 200,000 ≥ 250,000 ≥ 500,000 ≥ 750,000 ≥ 1,000,000
≥ 25 400 450 500 500 500 500
≥ 50 400 500 600 700 700 700
≥ 75 400 500 700 850 1,000 1,000
≥ 100 400 500 750 1,000 1,250 1,500
For SI: 1 foot = 304.8 mm.
  1. Contiguous floor area of the aircraft manufacturing facility having the indicated height.
  2. Minimum height from finished floor to bottom of ceiling or roof slab or deck.

412.7.1 Ancillary Areas

Rooms, areas and spaces ancillary to the primary manufacturing area shall be permitted to egress through such area having a minimum height as indicated in Table 412.7. Exit access travel distance within the ancillary room, area or space shall not exceed that indicated in Table 1017.2 based on the occupancy classification of that ancillary area. Total exit access travel distance shall not exceed that indicated in Table 412.7.

Related Code Sections


412.6 Special Detailed Requirements Based on Occupancy and Use, Aircraft Manufacturing Facilities
= 304.8 mm. Contiguous floor area of the aircraft manufacturing facility having the indicated height. Minimum height from finished floor ...
Building Code 2018 of Utah > 4 Special Detailed Requirements Based on Occupancy and Use > 412 Aircraft-Related Occupancies > 412.6 Aircraft Manufacturing Facilities
412.7 Special Detailed Requirements Based on Use and Occupancy, Aircraft Manufacturing Facilities
foot = 304.8 mm. Contiguous floor area of the aircraft manufacturing facility having the indicated height. Minimum height from finished floor ...
Building Code 2015 of Utah > 4 Special Detailed Requirements Based on Use and Occupancy > 412 Aircraft-Related Occupancies > 412.7 Aircraft Manufacturing Facilities
1017.2 Means of Egress, Limitations
amusement buildings. Section 412.7: For the distance limitations in aircraft manufacturing facilities. Section 1006.2.2.2: For the distance ...
Building Code 2015 of Utah > 10 Means of Egress > 1017 Exit Access Travel Distance > 1017.2 Limitations
1017.2 Means of Egress, Limitations
of the International Building Code : For the distance limitations in aircraft manufacturing facilities. Section 1006.2.2.2: For the distance ...
Fire Code 2018 of Utah > 10 Means of Egress > 1017 Exit Access Travel Distance > 1017.2 Limitations
1017.2 Means of Egress, Limitations
in special amusement buildings. Section 412.6: For the distance limitations in aircraft manufacturing facilities. Section 1006.2.2.2: For the distance ...
Building Code 2018 of Utah > 10 Means of Egress > 1017 Exit Access Travel Distance > 1017.2 Limitations
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE