E3904.7 Air Handling-Stud Cavity and Joist Spaces
JUMP TO FULL CODE CHAPTER
Where
wiring methods having a nonmetallic covering pass through
stud cavities and joist spaces used for air handling, such wiring
shall pass through such spaces perpendicular to the long
dimension of the spaces. [300.22(C) Exception]
Related Code Sections
E3904.7 Power and Lighting Distribution, Air Handling-Stud Cavity and Joist Spaces
Where
wiring methods having a nonmetallic covering pass through
stud cavities and joist spaces used for air handling, such wiring
shall pass through ...
2015 Michigan Residential Code > 39 Power and Lighting Distribution > E3904 General Installation Requirements > E3904.7 Air Handling-Stud Cavity and Joist Spaces
602.3 Duct Systems, Stud Cavity and Joist Space Plenums
Stud wall cavities
and the spaces between solid floor joists to be utilized as
air plenums shall comply with the following conditions:
Such ...
2015 Michigan Mechanical Code > 6 Duct Systems > 602 Plenums > 602.3 Stud Cavity and Joist Space Plenums
M1601.1.1 Duct Systems, Above-Ground Duct Systems
wall cavities shall not convey air from more than one floor level.
Stud wall cavities and joist-space plenums shall be isolated from adjacent ...
2015 Michigan Residential Code > 16 Duct Systems > M1601 Duct Construction > M1601.1 Duct Design > M1601.1.1 Above-Ground Duct Systems
R602.3.3 Wall Construction, Bearing Studs
Where joists, trusses or rafters
are spaced more than 16 inches (406 mm) on center and
the bearing studs below are spaced 24 inches (610 mm ...
2015 Michigan Residential Code > 6 Wall Construction > R602 Wood Wall Framing > R602.3 Design and Construction > R602.3.3 Bearing Studs
N1102.4.1.1 [RE] Energy Efficiency, (R402.4.1.1) Installation (Mandatory)
with the insulation and any gaps in the air barrier sealed. Access openings, drop down stair, or knee wall doors to unconditioned attic spaces shall be sealed ...
2015 Michigan Residential Code > 11 [RE] Energy Efficiency > N1102 Building Thermal Envelope > N1102.4 (R402.4) Air Leakage > N1102.4.1 (R402.4.1) Building Thermal Envelope > N1102.4.1.1 (R402.4.1.1) Installation (Mandatory)