A9.4.1 Air Films
2021 Oregon Energy Efficiency Specialty Code (OEESC) > Normative Appendix A Rated R-Value of Insulation and Assembly U-factor, C-Factor, and F-Factor Determinations > A9 Determination of Alternate Assembly U-Factors, C-Factors, F-Factors, or Heat Capacities > A9.4 Calculation Procedures and Assumptions > A9.4.1 Air Films
Go To Full Code Chapter
A9.4.1.1
Exterior surfaces are areas exposed to the wind.
A9.4.1.2
Semiexterior surfaces are protected surfaces that face attics, crawlspaces, and parking garages with natural or mechanical ventilation.
A9.4.1.3
Interior surfaces are surfaces within enclosed spaces.
Related Code Sections
A9.4.1 Normative Appendix A Rated R-Value of Insulation and Assembly U-factor, C-Factor, and F-Factor Determinations, Air Films
Prescribed R-values for air films shall be as follows: R-Value Condition 0.17 All exterior surfaces 0.46 All semiexterior ...
2021 Oregon Energy Efficiency Specialty Code (OEESC) > Normative Appendix A Rated R-Value of Insulation and Assembly U-factor, C-Factor, and F-Factor Determinations > A9 Determination of Alternate Assembly U-Factors, C-Factors, F-Factors, or Heat Capacities > A9.4 Calculation Procedures and Assumptions > A9.4.1 Air Films
A2.2.1 Normative Appendix A Rated R-Value of Insulation and Assembly U-factor, C-Factor, and F-Factor Determinations, General
film, R-0 for metal deck, and R-0.61 for interior air film heat flow up. Added insulation is continuous and uninterrupted by framing. The framing factor ...
A5.2.1 Normative Appendix A Rated R-Value of Insulation and Assembly U-factor, C-Factor, and F-Factor Determinations, General
for interior air film, heat flow down; R-1.23 for carpet and rubber pad; R-0.50 for 8 in. concrete; and R-0.46 for semiexterior air film. Added insulation ...
A3.3.1 Normative Appendix A Rated R-Value of Insulation and Assembly U-factor, C-Factor, and F-Factor Determinations, General
in. for 16 gage. The U-factors include R-0.17 for exterior air film, R-0.08 for stucco, R-0.56 for 0.625 in. gypsum board on the exterior, R-0.56 for 0.625 ...
A4.1 Normative Appendix A Rated R-Value of Insulation and Assembly U-factor, C-Factor, and F-Factor Determinations, General
not include R-values for exterior or interior air films or for soil. For insulated walls, the C-factor does include R-0.45 for 0.5 in. gypsum board ...