• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

603.6 Air Ducts and Air Connectors

NYC Mechanical Code 2014 > 6 Duct Systems > 603 Duct Construction and Installation > 603.6 Air Ducts and Air Connectors
JUMP TO FULL CODE CHAPTER
Air ducts, both metallic and nonmetallic, shall comply with Section 603.6.1. Air connectors, both metallic and nonmetallic, shall comply with Sections 606.6.2 and 603.6.3.

603.6.1 Air Ducts

Air ducts shall be permitted to be rigid or flexible and shall be constructed of materials that are reinforced and sealed to satisfy the requirements for the use of the air duct system, such as the supply air system, the return or exhaust air system, and the variable volume/pressure air system.

603.6.1.1 Materials

All air duct materials shall be suitable for continuous exposure to the temperature and humidity conditions of the environmental air in the air duct. Air ducts shall be constructed of any of the following materials:
  1. Iron, steel, aluminum, copper, concrete, masonry or clay tile.
  2. Class 0 or Class 1 rigid or flexible air ducts tested in accordance with UL 181 and installed in conformance with the conditions of the listing.
Exceptions:
  1. Class 0 or Class 1 rigid or flexible air duct shall not be used as a vertical air duct that is more than two stories in height.
  2. Class 0 or Class 1 rigid or flexible air ducts shall not be used for air ducts containing air at temperatures in excess of 250°F (121°C).
  3. Where the temperature of the conveyed air does not exceed 125°F (52°C) in normal service, negative pressure exhaust or return air ducts shall be permitted to be constructed of gypsum board having a maximum flame spread index/rating of 25 without evidence of continued progressive combustion and a maximum smoke developed index/rating of 50. Air ducts formed by gypsum boards shall have a surface temperature maintained above the air stream dew-point temperature, and shall not be used in air-handling systems utilizing evaporative coolers.
Exception: The maximum conveyed air temperature of 125°F (52°C) shall not apply to gypsum board material used for post-fire smoke purge.

603.6.1.2 Installation

The materials, thickness, construction, and installation of ducts shall provide structural strength and durability in conformance with recognized good practice. Air ducts shall be considered to be in compliance with this requirement where constructed and installed in accordance with the New York City Building Code. Where no standard exists for the construction of air ducts, they shall be constructed to withstand both the positive and negative pressures of the system.

603.6.2 Air Connectors

Air connectors are limited-use, flexible air ducts that are required to conform to other provisions applicable to air ducts and shall meet the following requirements:
  1. Air connectors shall conform to the requirements for Class 0 or Class 1 connectors when tested and approved in accordance with UL 181.
  2. Class 0 or Class 1 air connectors shall not be used for ducts containing air at temperatures in excess of 250°F (121°C).
  3. Air connector runs shall not exceed 14 feet (4267 mm) in length.
  4. Air connectors shall not penetrate any rated wall, partition, or shaft that is required to have a fire-resistance rating of 1 hour or more.
  5. Air connectors shall not pass through floors.

603.6.3 Flexible Air Duct and Air Connector Clearance

Flexible air ducts and air connectors shall be installed with a minimum clearance to an appliance as specified in the appliance manufacturer's installation instructions.

Related Code Sections


603.6 Duct Systems, Air Ducts and Air Connectors
Air ducts, both metallic and nonmetallic, shall comply with Section 603.6.1. Air connectors, both metallic and nonmetallic, shall comply ...
NYC Mechanical Code 2014 > 6 Duct Systems > 603 Duct Construction and Installation > 603.6 Air Ducts and Air Connectors
603.6 Duct Systems, Air Ducts and Air Connectors
Air ducts, both metallic and nonmetallic, shall comply with Sections 603.6.1 and 603.6.1.1. Air connectors, both metallic and nonmetallic, shall ...
NYC Mechanical Code 2008 > 6 Duct Systems > 603 Duct Construction and Installation > 603.6 Air Ducts and Air Connectors
603.6 Duct Systems, Air Ducts and Air Connectors
Air ducts, both metallic and nonmetallic, shall comply with Section 603.6.1. Air connectors, both metallic and nonmetallic, shall comply ...
NYC Mechanical Code 2022 > 6 Duct Systems > 603 Duct Construction and Installation > 603.6 Air Ducts and Air Connectors
603.6.1.1 Duct Systems, Materials
All air duct materials shall be suitable for continuous exposure to the temperature and humidity conditions of the environmental air in the air duct ...
NYC Mechanical Code 2022 > 6 Duct Systems > 603 Duct Construction and Installation > 603.6 Air Ducts and Air Connectors > 603.6.1 Air Ducts > 603.6.1.1 Materials
603.6.1.2 Duct Systems, Installation
good practice. Air ducts shall be considered to be in compliance with this requirement where constructed and installed in accordance with the New York ...
NYC Mechanical Code 2014 > 6 Duct Systems > 603 Duct Construction and Installation > 603.6 Air Ducts and Air Connectors > 603.6.1 Air Ducts > 603.6.1.2 Installation
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING