• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

**§28-320.8 Adjustment to Applicable Annual Building Emissions Limit for Calendar Years 2024-2029

NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > *320 Building Energy and Emissions Limits > **§28-320.8 Adjustment to Applicable Annual Building Emissions Limit for Calendar Years 2024-2029
JUMP TO FULL CODE CHAPTER
The department may grant an adjustment of the annual building emissions limit for calendar years 2024 through 2029 applicable to a covered building in existence on the effective date of this article where such covered building emissions in calendar year 2018 exceeds the building emissions limit as prescribed by section 28-320.3.1 by more than 40 percent, as reported to the department by a registered design professional. The adjustment shall result in a required building emissions limit that is 70 percent of the calendar year 2018 building emissions for the covered building. Such adjustment may be granted where all of the following conditions in items 1 through 3 are met:
  1. The owner of the covered building demonstrates that the building emissions in excess of the building emissions limit is attributable to special circumstances related to the use of the building, including but not limited to 24 hour operations, operations critical to human health and safety, high density occupancy, energy intensive communications technologies or operations, and energy-intensive industrial processes;
  2. The owner of the covered building demonstrates that the energy performance of the covered building is equivalent to a building in compliance with the New York city energy conservation code in effect on January 1, 2015; and
  3. The owner of the covered building has submitted a plan to the department setting forth a schedule of alterations to the covered building or changes to the operations and management of the covered building sufficient to ensure that the covered building will be in compliance with the annual building emissions limits for calendar years 2030 through 2034, as required by section 28-320.3.2.
*Section 28-320.8 was added by: Local Law 97 of 2019. This law has an effective date of November 15, 2019.

**Section 28-320.8 was amended by: Local Law 147 of 2019. This law has an effective date of November 15, 2019.

*§28-320.8.1 Effective Period

An adjustment granted pursuant to section 28-320.8 may be effective for the reporting years 2025 through 2030, as prescribed by section 28-320.3.7, provided that the certificate of occupancy has not been amended after December 31, 2018.

*Section 28-320.8.1 was added by: Local Law 97 of 2019. This law has an effective date of November 15, 2019.

*§28-320.8.1.1 Extension of Effective Period

The commissioner may also grant an extension of the effective period of the adjustment to applicable annual building emissions limit for calendar years 2030-2035, as prescribed by section 28-320.3.8. Such extension may be granted upon submission of a schedule of alterations to the covered building or changes to the operations and management of the covered building in accordance with section 28-320.8 sufficient to ensure that by 2035 the covered building will comply with a required building emissions limit that is 50 percent of the reported 2018 building emissions for the covered building.

*Section 28-320.8.1.1 was added by: Local Law 97 of 2019. This law has an effective date of November 15, 2019.

*§28-320.8.2 Application

An application for an adjustment shall be submitted to the department before July 1, 2021 in the form and manner determined by the department and certified by a registered design professional.

*Section 28-320.8.2 was added by: Local Law 97 of 2019. This law has an effective date of November 15, 2019.

Related Code Sections


*§28-320.8.2 Maintenance of Buildings, Application
An application for an adjustment shall be submitted to the department before July 1, 2021 in the form and manner determined by the department ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > *320 Building Energy and Emissions Limits > **§28-320.8 Adjustment to Applicable Annual Building Emissions Limit for Calendar Years 2024-2029 > *§28-320.8.2 Application
**§28-320.3.1.1 Maintenance of Buildings, Greenhouse Gas Coefficient of Energy Consumption for Calendar Years 2024 Through 2029
for calendar years 2024 through 2029: Utility electricity consumed on the premises of a covered building that is delivered to the building via ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > *320 Building Energy and Emissions Limits > *§28-320.3 Building Emissions Limits > *§28-320.3.1 Annual Building Emissions Limits 2024-2029 > **§28-320.3.1.1 Greenhouse Gas Coefficient of Energy Consumption for Calendar Years 2024 Through 2029
**§28-320.3.6.2 Maintenance of Buildings, Deductions From Reported Annual Building Emissions for Purchased Greenhouse Gas Offsets
For calendar years 2024 through 2029, a deduction shall be authorized for up to 10 percent of the annual building emissions limit. Such a deduction ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > *320 Building Energy and Emissions Limits > *§28-320.3 Building Emissions Limits > **§28-320.3.6 Deductions From Reported Annual Building Emissions > **§28-320.3.6.2 Deductions From Reported Annual Building Emissions for Purchased Greenhouse Gas Offsets
Article *320 Maintenance of Buildings, Building Energy and Emissions Limits
of the annual building emissions limit for calendar years 2024 through 2029 applicable to a covered building in existence on the effective date ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > *320 Building Energy and Emissions Limits
**§28-320.3.6 Maintenance of Buildings, Deductions From Reported Annual Building Emissions
be authorized for up to 10 percent of the annual building emissions limit. Such a deduction shall be authorized only where within the reporting calendar ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > *320 Building Energy and Emissions Limits > *§28-320.3 Building Emissions Limits > **§28-320.3.6 Deductions From Reported Annual Building Emissions
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE