• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1006.3.1 Adjacent Story

2020 Building Code of New York State > 10 Means of Egress > 1006 Number of Exits and Exit Access Doorways > 1006.3 Egress From Stories or Occupied Roofs > 1006.3.1 Adjacent Story
JUMP TO FULL CODE CHAPTER

The path of egress travel to an exit shall not pass through more than one adjacent story.

Exception: The path of egress travel to an exit shall be permitted to pass through more than one adjacent story in any of the following:
  1. In Group R-1, R-2 or R-3 occupancies, exit access stairways and ramps connecting four stories or less serving and contained within an individual dwelling unit, sleeping unit or live/work unit.
  2. Exit access stairways serving and contained within a Group R-3 congregate residence or a Group R-4 facility.
  3. Exit access stairways and ramps in open parking garages that serve only the parking garage.
  4. Exit access stairways and ramps serving open-air assembly seating complying with the exit access travel distance requirements of Section 1029.7.
  5. Exit access stairways and ramps between the balcony, gallery or press box and the main assembly floor in occupancies such as theaters, places of religious worship, auditoriums and sports facilities.

Related Code Sections


1004.1.1.3 Means of Egress, Adjacent Stories
Other than for the egress components designed for convergence in accordance with Section 1005.6, the occupant load from separate stories shall ...
Fire Code 2015 of New York State > 10 Means of Egress > 1004 Occupant Load > 1004.1 Design Occupant Load > 1004.1.1 Cumulative Occupant Loads > 1004.1.1.3 Adjacent Stories
1004.1.1.3 Means of Egress, Adjacent Stories
Other than for the egress components designed for convergence in accordance with Section 1005.6, the occupant load from separate stories shall ...
Building Code 2015 of New York State > 10 Means of Egress > 1004 Occupant Load > 1004.1 Design Occupant Load > 1004.1.1 Cumulative Occupant Loads > 1004.1.1.3 Adjacent Stories
1004.2.3 Means of Egress, Adjacent Stories
Other than for the egress components designed for convergence in accordance with Section 1005.6, the occupant load from separate stories shall ...
2020 Building Code of New York State > 10 Means of Egress > 1004 Occupant Load > 1004.2 Cumulative Occupant Loads > 1004.2.3 Adjacent Stories
1004.2.3 Means of Egress, Adjacent Stories
Other than for the egress components designed for convergence in accordance with Section 1005.6, the occupant load from separate stories shall ...
2020 Fire Code of NYS > 10 Means of Egress > 1004 Occupant Load > 1004.2 Cumulative Occupant Loads > 1004.2.3 Adjacent Stories
1006.3.1 Means of Egress, Adjacent Story
The path of egress travel to an exit shall not pass through more than one adjacent story . Exception: The path of egress travel to an exit ...
2020 Building Code of New York State > 10 Means of Egress > 1006 Number of Exits and Exit Access Doorways > 1006.3 Egress From Stories or Occupied Roofs > 1006.3.1 Adjacent Story
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE