A-102.8 Additions, Alterations and Repairs to Structures
Go To Full Code Chapter
Additions, alterations and repairs to an existing building or structure, or portion thereof shall conform to the requirements for new construction per the currently adopted technical codes. Additions, alterations and repairs shall not cause an existing building or structure to become unsafe, hazardous or overloaded.
Exception: At the option of the applicant or registered design professional in responsible charge, additions, alterations and repairs shall be permitted to comply with the applicable provisions of the Philadelphia Existing Building Code.
A-102.8.1 Additions, Alterations and Repairs to Systems
Additions, alterations, renovations and repairs to the following systems and installations shall conform to the requirements for new systems and installations without requiring any portion of the existing systems and installations to comply with all of the requirements of the applicable technical codes. Additions, alterations and repairs shall not cause an existing system or installation to become unsafe, hazardous or overloaded.
- Electrical installations
- Fuel gas installations
- Mechanical systems
- Plumbing systems
- Service water-heating systems
Upcodes Diagrams
Related Code Sections
A-102.8 General, Additions, Alterations and Repairs to Structures
Additions, alterations and repairs to an existing building or structure, or portion thereof shall conform to the requirements for new construction ...
R102.7.1 Scope and Administration, Additions, Alterations or Repairs
Additions, alterations or repairs to any structure shall conform to the requirements for a new structure without requiring the existing structure ...
R501.1 [RE] Existing Buildings, Scope
The provisions of this chapter shall control the alteration, repair, addition and change of occupancy of existing buildings and structures ...
3302.1 Safeguards During Construction, Alterations, Repairs and Additions
, repairs or additions to any building or structure. Exceptions: Where such required elements or devices are being altered or repaired, adequate ...