• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.1052(j)(4)(iv) Additional Surveillance

OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1052 Methylene Chloride > 1910.1052(j) Medical Surveillance > 1910.1052(j)(4) Frequency of Medical Surveillance > 1910.1052(j)(4)(iv) Additional Surveillance
JUMP TO FULL CODE CHAPTER
The employer shall provide additional medical surveillance at frequencies other than those listed above when recommended in the written medical opinion. (For example, the physician or other licensed health care professional may determine an examination is warranted in less than 36 months for employees younger than 45 years of age based upon evaluation of the results of the annual medical and work history.)

Related Code Sections


1910.1052(j)(4)(iv) Toxic and Hazardous Substances, Additional Surveillance
The employer shall provide additional medical surveillance at frequencies other than those listed above when recommended in the written medical ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1052 Methylene Chloride > 1910.1052(j) Medical Surveillance > 1910.1052(j)(4) Frequency of Medical Surveillance > 1910.1052(j)(4)(iv) Additional Surveillance
1910.1028(i)(5)(iv) Toxic and Hazardous Substances,
The hematologist's or internist's evaluation shall include a determination as to the need for additional tests, and the employer shall assure ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1028 Benzene > 1910.1028(i) Medical Surveillance > 1910.1028(i)(5) Additional Examinations and Referrals > 1910.1028(i)(5)(iv)
1910.1028(i)(5)(i)(C) Toxic and Hazardous Substances,
The leukocyte count is below 4,000 per mm 3 or there is an abnormal differential count ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1028 Benzene > 1910.1028(i) Medical Surveillance > 1910.1028(i)(5) Additional Examinations and Referrals > 1910.1028(i)(5)(i) > 1910.1028(i)(5)(i)(C)
1910.1028(i)(5)(ii) Toxic and Hazardous Substances,
If the abnormality persists, the examining physician shall refer the employee to a hematologist or an internist for further evaluation unless ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1028 Benzene > 1910.1028(i) Medical Surveillance > 1910.1028(i)(5) Additional Examinations and Referrals > 1910.1028(i)(5)(ii)
1910.1028(i)(5)(iii) Toxic and Hazardous Substances,
The employer shall provide the hematologist or internist with the information required to be provided to the physician under paragraph (i)(6 ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1028 Benzene > 1910.1028(i) Medical Surveillance > 1910.1028(i)(5) Additional Examinations and Referrals > 1910.1028(i)(5)(iii)
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING