914.5 Additional Fixtures
JUMP TO FULL CODE CHAPTER
Fixtures, other than the circuit-vented fixtures, are permitted to discharge to the horizontal branch drain. Such fixtures shall be located on the same floor as the circuit-vented fixtures and shall be either individually or common vented.
Related Code Sections
914.5 Vents, Additional Fixtures
Fixtures, other than the circuit-vented fixtures, are permitted to discharge to the horizontal branch drain. Such fixtures shall be located ...
Georgia State Minimum Standard Plumbing Code > 9 Vents > 914 Circuit Venting > 914.5 Additional Fixtures
914.5 Vents, Additional Fixtures
Fixtures, other than the circuit-vented fixtures, are permitted to discharge to the horizontal branch drain . Such fixtures shall be located ...
Georgia State Minimum Standard Plumbing Code > 9 Vents > 914 Circuit Venting > 914.5 Additional Fixtures
P3110.4 Vents, Additional Fixtures
Fixtures, other than circuit-vented fixtures, shall be permitted to discharge to the horizontal branch drain. Such fixtures shall be located ...
Georgia State Minimum Standard One and Two Family Dwelling Code > 31 Vents > P3110 Circuit Venting > P3110.4 Additional Fixtures
Section 1109 Storm Drainage, Combined Sanitary and Storm System
exceeds 256 fixture units, each additional fixture unit shall be considered the equivalent of 15.6 square feet (1.5 m 2 ) of drainage area. These values ...
Georgia State Minimum Standard Plumbing Code > 11 Storm Drainage > 1109 Combined Sanitary and Storm System
P3108.1 Vents, Horizontal Wet Vent Permitted
the bathroom groups shall connect to the wet-vented horizontal branch drain. Any additional fixtures shall discharge downstream of the horizontal wet ...
Georgia State Minimum Standard One and Two Family Dwelling Code > 31 Vents > P3108 Wet Venting > P3108.1 Horizontal Wet Vent Permitted