• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

914.5 Additional Fixtures

Georgia State Minimum Standard Plumbing Code > 9 Vents > 914 Circuit Venting > 914.5 Additional Fixtures
JUMP TO FULL CODE CHAPTER
Fixtures, other than the circuit-vented fixtures, are permitted to discharge to the horizontal branch drain. Such fixtures shall be located on the same floor as the circuit-vented fixtures and shall be either individually or common vented.

Related Code Sections


914.5 Vents, Additional Fixtures
Fixtures, other than the circuit-vented fixtures, are permitted to discharge to the horizontal branch drain. Such fixtures shall be located ...
Georgia State Minimum Standard Plumbing Code > 9 Vents > 914 Circuit Venting > 914.5 Additional Fixtures
914.5 Vents, Additional Fixtures
Fixtures, other than the circuit-vented fixtures, are permitted to discharge to the horizontal branch drain . Such fixtures shall be located ...
Georgia State Minimum Standard Plumbing Code > 9 Vents > 914 Circuit Venting > 914.5 Additional Fixtures
P3110.4 Vents, Additional Fixtures
Fixtures, other than circuit-vented fixtures, shall be permitted to discharge to the horizontal branch drain. Such fixtures shall be located ...
Georgia State Minimum Standard One and Two Family Dwelling Code > 31 Vents > P3110 Circuit Venting > P3110.4 Additional Fixtures
Section 1109 Storm Drainage, Combined Sanitary and Storm System
exceeds 256 fixture units, each additional fixture unit shall be considered the equivalent of 15.6 square feet (1.5 m 2 ) of drainage area. These values ...
Georgia State Minimum Standard Plumbing Code > 11 Storm Drainage > 1109 Combined Sanitary and Storm System
P3108.1 Vents, Horizontal Wet Vent Permitted
the bathroom groups shall connect to the wet-vented horizontal branch drain. Any additional fixtures shall discharge downstream of the horizontal wet ...
Georgia State Minimum Standard One and Two Family Dwelling Code > 31 Vents > P3108 Wet Venting > P3108.1 Horizontal Wet Vent Permitted
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE