• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1607.5.1 Actual Loads

NYC Building Code 2014 > 16 Structural Design > 1607 Live Loads > 1607.5 Partition Loads > 1607.5.1 Actual Loads
JUMP TO FULL CODE CHAPTER
Where actual partition weights are used, the uniform design live load may be omitted from the strip of floor area under each partition.

Related Code Sections


1607.5.1 Structural Design, Actual Loads
Where actual partition weights are used, the uniform design live load may be omitted from the strip of floor area under each partition ...
NYC Building Code 2008 > 16 Structural Design > 1607 Live Loads > 1607.5 Partition Loads > 1607.5.1 Actual Loads
1607.5.1 Structural Design, Actual Loads
Where actual partition weights are used, the uniform design live load may be omitted from the strip of floor area under each partition ...
NYC Building Code 2014 > 16 Structural Design > 1607 Live Loads > 1607.5 Partition Loads > 1607.5.1 Actual Loads
1607.5.1 Structural Design, Actual Loads
Where actual partition weights are used, the uniform design live load may be omitted from the strip of floor area under each partition ...
NYC Building Code 2022 > 16 Structural Design > 1607 Live Loads > 1607.5 Partition Loads > 1607.5.1 Actual Loads
3307.3.4 Safeguards During Construction or Demolition, Openings
Openings in sidewalk sheds, fences, barriers, and railings for loading and unloading purposes shall be kept closed at all times except during actual ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3307 Protection of Pedestrians > 3307.3 Protection of Sidewalks, Walkways and Temporary Walkways > 3307.3.4 Openings
§27-555 Loads, Partition Loads
Weights of all partitions shall be considered, using either actual weights at locations shown on the plans or the equivalent uniform load given ...
NYC 1968 Code (Vol I) > 9 Loads > 2 Dead Loads > §27-555 Partition Loads
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING