612.1.2 Actual Energy Use Intensity (EUI
JUMP TO FULL CODE CHAPTER
a).
The actual energy use intensity (EUIa) of the building and building site shall be expressed in accordance with this section. On-site renewable energy generation in excess of the generation requirements of Section 610 shall be included in the calculation of the EUIa.
The EUIa shall be determined in accordance with Equation 6-7 and Sections 612.1.2.1.
where:
The actual energy use intensity (EUIa) of the building and building site shall be expressed in accordance with this section. On-site renewable energy generation in excess of the generation requirements of Section 610 shall be included in the calculation of the EUIa.
The EUIa shall be determined in accordance with Equation 6-7 and Sections 612.1.2.1.
where:
EUIa | = | the energy use intensity of the building and building site. |
AEUconsumption | = | the annual energy consumed by the building and building site from all forms of energy specified in Sections 603.3.1 through 603.3.6 and converted to source Btus in accordance with Section 602.2.1.2. |
AEUrenewable | = | the annual energy produced by onsite renewable energy systems in excess of the production required by Section 610 and converted to source Btus by multiplying onsite Btu production by a factor of 1. |
TCFA | = | the total conditioned floor area of the building. |
The AEUs shall be determined from metering, utility billing or other form of measurement in accordance with Section 603.
Related Code Sections
612.1.2 Energy Conservation, Efficiency and Co2e Emission Reduction, Actual Energy Use Intensity (EUI
a ). The actual energy use intensity (EUI a ) of the building and building site shall be expressed in accordance with this section. On-site ...
Green Construction Code 2015 > 6 Energy Conservation, Efficiency and Co2e Emission Reduction > 612 Outcome-Based Pathway Requirements > 612.1 Outcome-Based Requirements > 612.1.2 Actual Energy Use Intensity (EUI
612.2 Energy Conservation, Efficiency and Co2e Emission Reduction, Annual Direct and Indirect Co2e Emissions
of determining compliance with the provisions of Section 612.2, the CO 2 e emissions associated with onsite non-renewable energy use shall be calculated ...
Green Construction Code 2015 > 6 Energy Conservation, Efficiency and Co2e Emission Reduction > 612 Outcome-Based Pathway Requirements > 612.2 Annual Direct and Indirect Co2e Emissions
602.1.1 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, zEPI
calculated in accordance with Section 602.1.2.
EUI
=
the base annual energy use index in source kBtu/sf-y for a baseline building and its site ...
Green Construction Code 2012 > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 602 Modeled Performance Pathway Requirements > 602.1 Performance-Based Compliance > 602.1.1 zEPI
602.1 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Performance-Based Compliance
× (EUIp/EUI)
(Equation 6-1)
where:
EUIp
=
the proposed energy use index in source kBtu/sf-y for the proposed design of the building ...
Green Construction Code 2012 > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 602 Modeled Performance Pathway Requirements > 602.1 Performance-Based Compliance
321.2.2 General Compliance, Illumination Intensity
For outdoor pools, any combination of overhead and underwater lighting shall provide maintained illumination not less than 10 horizontal foot ...
Swimming Pool and Spa Code 2015 > 3 General Compliance > 321 Lighting > 321.2 Artificial Lighting Required > 321.2.2 Illumination Intensity