• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2107.2 ACI 530/ASCE 5/TMS 402, Section 2.1.2, Load Combinations

2010 Building Code of NY > 21 Masonry > 2107 Allowable Stress Design > 2107.2 ACI 530/ASCE 5/TMS 402, Section 2.1.2, Load Combinations
JUMP TO FULL CODE CHAPTER
Delete Section 2.1.2.1.

Related Code Sections


2107.2 Masonry, ACI 530/ASCE 5/TMS 402, Section 2.1.2, Load Combinations
Delete Section 2.1.2.1 ...
2010 Building Code of NY > 21 Masonry > 2107 Allowable Stress Design > 2107.2 ACI 530/ASCE 5/TMS 402, Section 2.1.2, Load Combinations
2106.1.1 Masonry, Basic Seismic-Force-Resisting System
with the requirements of Section 1.14.2.2.4 of ACI 530/ASCE 5/TMS 402 and shall be designed by Chapter 4, Section 4.4.3, of ACI 530/ASCE 5/TMS 402 for flexural ...
2010 Building Code of NY > 21 Masonry > 2106 Seismic Design > 2106.1 Seismic Design Requirements for Masonry > 2106.1.1 Basic Seismic-Force-Resisting System
2109.1 Masonry, General
Empirically designed masonry shall conform to the requirements of Appendix A of TMS 402/ACI 530/ASCE 5, except where otherwise noted in this section ...
Building Code 2015 of New York State > 21 Masonry > 2109 Empirical Design of Masonry > 2109.1 General
2101.2 Masonry, Design Methods
Prestressed masonry shall be designed in accordance with Chapters 1 and 4 of ACI 530/ASCE 5/TMS 402 and Section 2106. Special inspection during construction ...
2010 Building Code of NY > 21 Masonry > 2101 General > 2101.2 Design Methods
1405.6 Exterior Walls, Anchored Masonry Veneer
to the requirements of Section 12.2.2.10 of TMS 402/ACI 530/ASCE 5 ...
Building Code 2015 of New York State > 14 Exterior Walls > 1405 Installation of Wall Coverings > 1405.6 Anchored Masonry Veneer
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE