1905.1.1 ACI 318, Section 2.3

Building Code 2015 of Utah > 19 Concrete > 1905 Modifications to Aci 318 > 1905.1 General > 1905.1.1 ACI 318, Section 2.3
JUMP TO FULL CODE CHAPTER
Modify existing definitions and add the following definitions to ACI 318, Section 2.3.

DESIGN DISPLACEMENT. Total lateral displacement expected for the design-basis earthquake, as specified by Section 12.8.6 of ASCE 7.

DETAILED PLAIN CONCRETE STRUCTURAL WALL. A wall complying with the requirements of Chapter 14, including 14.6.2.

ORDINARY PRECAST STRUCTURAL WALL. A precast wall complying with the requirements of Chapters 1 through 13, 15, 16 and 19 through 26.

ORDINARY REINFORCED CONCRETE STRUCTURAL WALL. A cast-in-place wall complying with the requirements of Chapters 1 through 13, 15, 16 and 19 through 26.

ORDINARY STRUCTURAL PLAIN CONCRETE WALL. A wall complying with the requirements of Chapter 14, excluding 14.6.2.

SPECIAL STRUCTURAL WALL. A cast-in-place or precast wall complying with the requirements of 18.2.4 through 18.2.8, 18.10 and 18.11, as applicable, in addition to the requirements for ordinary reinforced concrete structural walls or ordinary precast structural walls, as applicable. Where ASCE 7 refers to a "special reinforced concrete structural wall," it shall be deemed to mean a "special structural wall."
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


1905.1.1 Concrete, ACI 318, Section 2.3
Modify existing definitions and add the following definitions to ACI 318, Section 2.3. DESIGN DISPLACEMENT. Total lateral displacement expected ...
Building Code 2018 of Utah > 19 Concrete > 1905 Modifications to Aci 318 > 1905.1 General > 1905.1.1 ACI 318, Section 2.3
1905.1.1 Concrete, ACI 318, Section 2.3
Modify existing definitions and add the following definitions to ACI 318, Section 2.3. DESIGN DISPLACEMENT. Total lateral displacement ...
Building Code 2015 of Utah > 19 Concrete > 1905 Modifications to Aci 318 > 1905.1 General > 1905.1.1 ACI 318, Section 2.3
1905.1.8 Concrete, ACI 318, Section 17.2.3
Modify ACI 318 Sections 17.2.3.4.2, 17.2.3.4.3(d) and 17.2.3.5.2 to read as follows: 17.2.3.4.2 ‒ Where the tensile component of the strength ...
Building Code 2015 of Utah > 19 Concrete > 1905 Modifications to Aci 318 > 1905.1 General > 1905.1.8 ACI 318, Section 17.2.3
1905.1.2 Concrete, ACI 318, Section 18.2.1
Modify ACI 318 Sections 18.2.1.2 and 18.2.1.6 to read as follows: 18.2.1.2 – Structures assigned to Seismic Design Category A shall satisfy ...
Building Code 2018 of Utah > 19 Concrete > 1905 Modifications to Aci 318 > 1905.1 General > 1905.1.2 ACI 318, Section 18.2.1
1905.1.2 Concrete, ACI 318, Section 18.2.1
Modify ACI 318 Sections 18.2.1.2 and 18.2.1.6 to read as follows: 18.2.1.2 ‒ Structures assigned to Seismic Design Category A shall satisfy ...
Building Code 2015 of Utah > 19 Concrete > 1905 Modifications to Aci 318 > 1905.1 General > 1905.1.2 ACI 318, Section 18.2.1
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Free Law Contact Careers Terms Privacy Press Kit
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US