Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1107.6.1.1 Accessible Units

Building Code 2018 of Illinois > 11 Accessibility > 1107 Dwelling Units and Sleeping Units > 1107.6 Group R > 1107.6.1 Group R-1 > 1107.6.1.1 Accessible Units
JUMP TO FULL CODE CHAPTER
Accessible dwelling units and sleeping units shall be provided in accordance with Table 1107.6.1.1. On a multiple-building site, where structures contain more than 50 dwelling units or sleeping units, the number of Accessible units shall be determined per structure. On a multiple-building site, where structures contain 50 or fewer dwelling units or sleeping units, all dwelling units and sleeping units on a site shall be considered to determine the total number of Accessible units. Accessible units shall be dispersed among the various classes of units.
TABLE 1107.6.1.1
ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS
TOTAL NUMBER OF
UNITS PROVIDED
MINIMUM REQUIRED NUMBER OF
ACCESSIBLE UNITS WITHOUT
ROLL-IN SHOWERS
MINIMUM REQUIRED NUMBER OF
ACCESSIBLE UNITS WITH
ROLL-IN SHOWERS
TOTAL NUMBER OF
REQUIRED ACCESSIBLE UNITS
1 to 25101
26 to 50202
51 to 75314
76 to 100415
101 to 150527
151 to 200628
201 to 3007310
301 to 4008412
401 to 5009413
501 to 1,0002% of total1% of total3% of total
Over 1,00020, plus 1 for each 100,
or fraction thereof, over 1,000
10 plus 1 for each 100, or
fraction thereof, over 1,000
30 plus 2 for each 100, or
fraction thereof, over 1,000

Related Code Sections


1107.5.1.1 Accessibility, Accessible Units
In Group I-1, Condition 1, at least 4 percent, but not less than one, of the dwelling units and sleeping units shall be Accessible units . In ...
Building Code 2018 of Illinois > 11 Accessibility > 1107 Dwelling Units and Sleeping Units > 1107.5 Group I > 1107.5.1 Group I-1 > 1107.5.1.1 Accessible Units
1108.5.1.1 Accessibility, Accessible Units
In Group I-1, Condition 1, at least 4 percent, but not less than one, of the dwelling units and sleeping units shall be Accessible units ...
Building Code 2021 of Illinois > 11 Accessibility > 1108 Dwelling Units and Sleeping Units > 1108.5 Group I > 1108.5.1 Group I-1 > 1108.5.1.1 Accessible Units
1108.5.2.1 Accessibility, Accessible Units
At least 50 percent but not less than one of each type of the dwelling units and sleeping units shall be Accessible units . Exceptions ...
Building Code 2021 of Illinois > 11 Accessibility > 1108 Dwelling Units and Sleeping Units > 1108.5 Group I > 1108.5.2 Group I-2 Nursing Homes > 1108.5.2.1 Accessible Units
1108.5.3.1 Accessibility, Accessible Units
At least 10 percent, but not less than one, of the dwelling units and sleeping units shall be Accessible units . Exception: Entry doors ...
Building Code 2021 of Illinois > 11 Accessibility > 1108 Dwelling Units and Sleeping Units > 1108.5 Group I > 1108.5.3 Group I-2 Hospitals > 1108.5.3.1 Accessible Units
1108.6.1.1 Accessibility, Accessible Units
Accessible dwelling units and sleeping units shall be provided in accordance with Table 1108.6.1.1. On a multiple-building site, where structures ...
Building Code 2021 of Illinois > 11 Accessibility > 1108 Dwelling Units and Sleeping Units > 1108.6 Group R > 1108.6.1 Group R-1 > 1108.6.1.1 Accessible Units
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING