1002.11.2 Accessible Toilet and Bathing Facility
JUMP TO FULL CODE CHAPTER
At least one toilet and bathing facility shall comply with Section 603. At least one lavatory, one water closet and either a bathtub or shower within the unit shall comply with Sections 604 through 610. The accessible toilet and bathing fixtures shall be in a single toilet/bathing area, such that travel between fixtures does not require travel through other parts of the unit.
If vanity counter top space is provided in dwelling or sleeping units not required to be Accessible units within the same facility, equivalent vanity counter top space, in terms of size and proximity to the lavatory, shall also be provided in Accessible units.
Mirrors above accessible lavatories shall have the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the floor.
Related Code Sections
1002.11.2 Dwelling Units and Sleeping Units, Accessible Toilet and Bathing Facility
At least one toilet and bathing facility shall comply with Section 603. At least one lavatory, one water closet and either a bathtub or shower within ...
Accessible and Usable Buildings and Facilities 2009 of New York State > 10 Dwelling Units and Sleeping Units > 1002 Accessible Units > 1002.11 Toilet and Bathing Facilities > 1002.11.2 Accessible Toilet and Bathing Facility
609.1 Plumbing Elements and Facilities, General
Grab bars in accessible toilet or bathing facilities shall comply with Section 609 ...
Accessible and Usable Buildings and Facilities 2009 of New York State > 6 Plumbing Elements and Facilities > 609 Grab Bars > 609.1 General
605.1.9 Alterations - Level 1, Toilet Rooms
Where it is technically infeasible to alter existing toilet and bathing facilities to be accessible, an accessible unisex toilet or bathing facility ...
2010 Existing Building Code of NY > 6 Alterations - Level 1 > 605 Accessibility > 605.1 General > 605.1.9 Toilet Rooms
308.8.9 Prescriptive Compliance Method, Toilet Rooms
Where it is technically infeasible to alter existing toilet and bathing facilities to be accessible, an accessible unisex toilet or bathing facility ...
2010 Existing Building Code of NY > 3 Prescriptive Compliance Method > 308 Accessibility for Existing Buildings [B] > 308.8 Scoping for Alterations > 308.8.9 Toilet Rooms
E107.1 Supplementary Accessibility Requirements, Signs
Required accessible portable toilets and bathing facilities shall be identified by the International Symbol of Accessibility ...
Building Code 2015 of New York State > E Supplementary Accessibility Requirements > E107 Signage > E107.1 Signs