Section 1130A Accessible Route Within Covered Multifamily Dwelling Units
JUMP TO FULL CODE CHAPTER
An accessible route shall be provided through all rooms and spaces of the dwelling unit. The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures. For the purpose of this section, "accessible routes" may include hallways, corridors and ramps.
Exception: An accessible route is not required from the interior of the unit into a basement or garage, except as provided in Section 1105A.1.
The accessible route into and throughout covered multifamily dwelling units shall be at least 36 inches (914 mm) wide.
Related Code Sections
Section 1130A Housing Accessibility, Accessible Route Within Covered Multifamily Dwelling Units
The accessible route into and throughout covered multifamily dwelling units shall be at least 36 inches (914 mm) wide ...
Los Angeles Building Code > 11A Housing Accessibility > 1130A Accessible Route Within Covered Multifamily Dwelling Units
1119A.1 Housing Accessibility, General
of the building, accessible building entrances and to covered multifamily dwelling units. The accessible route shall, to the maximum extent feasible, coincide ...
Los Angeles Building Code > 11A Housing Accessibility > 1119A Interior Accessible Routes > 1119A.1 General
1110A.1 Housing Accessibility, General
spaces, elements, and covered multifamily dwelling units. An accessible route shall connect at least one accessible entrance of each covered ...
Los Angeles Building Code > 11A Housing Accessibility > 1110A Exterior Accessible Routes > 1110A.1 General
Section 1110A Housing Accessibility, Exterior Accessible Routes
spaces, elements, and covered multifamily dwelling units. An accessible route shall connect at least one accessible entrance of each covered ...
1104A.1 Housing Accessibility, General
All ground-floor dwelling units in nonelevator buildings shall be adaptable and on an accessible route, unless an accessible route is not required ...
Los Angeles Building Code > 11A Housing Accessibility > 1104A Covered Multifamily Dwellings > 1104A.1 General