• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1009.1 Accessible Means of Egress Required

Building Code 2021 of Illinois > 10 Means of Egress > 1009 Accessible Means of Egress > 1009.1 Accessible Means of Egress Required
JUMP TO FULL CODE CHAPTER
ILLUSTRATION
Accessible means of egress shall comply with this section. Accessible spaces shall be provided with not less than one accessible means of egress. Where more than one means of egress is required by Section 1006.2 or 1006.3 from any accessible space, each accessible portion of the space shall be served by not less than two accessible means of egress.
Exceptions:
  1. One accessible means of egress is required from an accessible mezzanine level in accordance with Section 1009.3, 1009.4 or 1009.5.
  2. In assembly areas with ramped aisles or stepped aisles, one accessible means of egress is permitted where the common path of egress travel is accessible and meets the requirements in Section 1030.8.

Related Code Sections


1009.1 Means of Egress, Accessible Means of Egress Required
Where more than one means of egress is required by Section 1006.2 or 1006.3 from any accessible space, each accessible portion of the space shall ...
Building Code 2018 of Illinois > 10 Means of Egress > 1009 Accessible Means of Egress > 1009.1 Accessible Means of Egress Required
1009.1 Means of Egress, Accessible Means of Egress Required
Where more than one means of egress is required by Section 1006.2 or 1006.3 from any accessible space, each accessible portion of the space shall ...
Building Code 2021 of Illinois > 10 Means of Egress > 1009 Accessible Means of Egress > 1009.1 Accessible Means of Egress Required
506.1 General Site and Building Elements, Accessible Means of Egress Required
Where more than one means of egress are required by the applicable building code from any accessible space, each accessible portion of the space shall ...
2018 Illinois Accessibility Code > 5 General Site and Building Elements > 506 Accessible Means of Egress > 506.1 Accessible Means of Egress Required
306.7.2 Provisions for All Compliance Methods, Accessible Means of Egress
Accessible means of egress required by Chapter 10 of the International Building Code are not required to be added in existing facilities ...
Existing Building Code 2021 of Illinois > 3 Provisions for All Compliance Methods > 306 Accessibility for Existing Buildings > 306.7 Alterations > 306.7.2 Accessible Means of Egress
1007.1.3 Means of Egress, Remoteness of Exit Access Stairways or Ramps
Where two exit access stairways or ramps provide the required means of egress to exits at another story, the required separation distance shall ...
Building Code 2018 of Illinois > 10 Means of Egress > 1007 Exit and Exit Access Doorway Configuration > 1007.1 General > 1007.1.3 Remoteness of Exit Access Stairways or Ramps
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING