1204.1 Accessibility Requirements
JUMP TO FULL CODE CHAPTER
The provisions of Sections 705, 806 and 906, as applicable, shall apply to facilities designated as historic structures that undergo alterations, unless technically infeasible. Where compliance with the requirements for accessible routes, entrances or toilet rooms would threaten or destroy the historic significance of the building or facility, as determined by the code official, the alternative requirements of Sections 1204.1.1 through 1204.1.4 for that element shall be permitted.
Exception: Type B dwelling or sleeping units required by Section 1107 of the International Building Code are not required to be provided in historical buildings.
At least one accessible route from a site arrival point to an accessible entrance shall be provided.
An accessible route from an accessible entrance to public spaces on the level of the accessible entrance shall be provided.
At least one main entrance shall be accessible.
Exceptions:
- If a main entrance cannot be made accessible, an accessible nonpublic entrance that is unlocked while the building is occupied shall be provided; or
- If a main entrance cannot be made accessible, a locked accessible entrance with a notification system or remote monitoring shall be provided.
Where toilet rooms are provided, at least one accessible family or assisted-use toilet room complying with Section 1109.2.1 of the International Building Code shall be provided.
Related Code Sections
1104.1 Historic Buildings, Accessibility Requirements
infeasible. Where compliance with the requirements for accessible routes, entrances, or toilet facilities would threaten or destroy the historic ...
2010 Existing Building Code of NY > 11 Historic Buildings > 1104 Alterations > 1104.1 Accessibility Requirements
1105.15 Historic Buildings, Accessibility Requirements
technically infeasible. Where compliance with the requirements for accessible routes, ramps, entrances, or toilet facilities would threaten or destroy ...
2010 Existing Building Code of NY > 11 Historic Buildings > 1105 Change of Occupancy > 1105.15 Accessibility Requirements
1204.1 Historic Buildings, Accessibility Requirements
, unless technically infeasible . Where compliance with the requirements for accessible routes, entrances or toilet rooms would threaten or destroy ...
Existing Building Code 2015 of New York State > 12 Historic Buildings > 1204 Alterations > 1204.1 Accessibility Requirements
1205.15 Historic Buildings, Accessibility Requirements
technically infeasible . Where compliance with the requirements for accessible routes, ramps, entrances, or toilet rooms would threaten or destroy the historic ...
Existing Building Code 2015 of New York State > 12 Historic Buildings > 1205 Change of Occupancy > 1205.15 Accessibility Requirements
1301.2.5 Performance Compliance Methods, Accessibility Requirements
All portions of the buildings proposed for change of occupancy shall conform to the accessibility provisions of Chapter 11 of the Building Code ...
2010 Existing Building Code of NY > 13 Performance Compliance Methods > 1301 General > 1301.2 Applicability > 1301.2.5 Accessibility Requirements