507.26 Accessibility for Service
JUMP TO FULL CODE CHAPTER
All appliances shall be located with respect to building construction and other equipment so as to permit access to the appliance. Sufficient clearance shall be maintained to permit cleaning of heating surfaces; the replacement of filters, blowers, motors, burners, controls, and vent connections; the lubrication of moving parts where necessary; the adjustment and cleaning of burners and pilots; I and the proper functioning of explosion vents, if provided. For attic installation, the passageway and servicing area adjacent to the appliance shall be floored. [NFPA 54:9.2.1]
Related Code Sections
507.26 Water Heaters, Accessibility for Service
All appliances shall be located with respect to building construction and other equipment so as to permit access to the appliance. Sufficient ...
2021 Oregon Plumbing Specialty Code > 5 Water Heaters > 507.0 Appliance and Equipment Installation Requirements > 507.26 Accessibility for Service
Section 306 General Regulations, Access and Service Space
Appliances, controls devices, heat exchangers and HVAC system components that utilize energy shall be accessible for inspection, service, repair ...
306.3.1 General Regulations, Electrical Requirements
A luminaire controlled by a switch located at the required passageway opening and a receptacle outlet shall be provided at or near the appliance ...
2019 Oregon Mechanical Specialty Code > 3 General Regulations > 306 Access and Service Space > 306.3 Appliances in Attics > 306.3.1 Electrical Requirements
306.4.1 General Regulations, Electrical Requirements
A luminaire controlled by a switch located at the required passageway opening and a receptacle outlet shall be provided at or near the appliance ...
2019 Oregon Mechanical Specialty Code > 3 General Regulations > 306 Access and Service Space > 306.4 Appliances Under Floors > 306.4.1 Electrical Requirements
306.5.1 General Regulations, Sloped Roofs
on each side of the appliance or equipment to which access is required for service, repair or maintenance. The platform shall be not less than 30 ...
2019 Oregon Mechanical Specialty Code > 3 General Regulations > 306 Access and Service Space > 306.5 Equipment and Appliances on Roofs or Elevated Structures > 306.5.1 Sloped Roofs