N1102.2.4 (R402.2.4) Access Hatches and Doors

Residential Code 2015 of Utah > 11 [RE] Energy Efficiency > N1102 (R402) Building Thermal Envelope > N1102.2 (R402.2) Specific Insulation Requirements (Prescriptive) > N1102.2.4 (R402.2.4) Access Hatches and Doors
JUMP TO FULL CODE CHAPTER
Access doors from conditioned spaces to unconditioned spaces such as attics and crawl spaces shall be weatherstripped and insulated to a level equivalent to the insulation on the surrounding surfaces. Access shall be provided to all equipment that prevents damaging or compressing the insulation. A wood-framed or equivalent baffle or retainer is required to be provided when loose-fill insulation is installed, the purpose of which is to prevent the loose-fill insulation from spilling into the living space when the attic access is opened, and to provide a permanent means of maintaining the installed R-value of the loose-fill insulation.

Exception: Vertical doors that provide access from conditioned to unconditioned spaces shall be permitted to meet the fenestration requirements of Table N1102.1.2 based on the applicable climate zone specified in Section N1101.7.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


N1102.2.4 [RE] Energy Efficiency, (R402.2.4) Access Hatches and Doors
Access doors from conditioned spaces to unconditioned spaces such as attics and crawl spaces shall be weatherstripped and insulated to a level ...
Residential Code 2015 of Utah > 11 [RE] Energy Efficiency > N1102 (R402) Building Thermal Envelope > N1102.2 (R402.2) Specific Insulation Requirements (Prescriptive) > N1102.2.4 (R402.2.4) Access Hatches and Doors
R402.2.4 [RE] Residential Energy Efficiency, Access Hatches and Doors
Access doors from conditioned spaces to unconditioned spaces such as attics and crawl spaces shall be weatherstripped and insulated to a level ...
Energy Conservation Code 2015 of Utah > 4 [RE] Residential Energy Efficiency > R402 Building Thermal Envelope > R402.2 Specific Insulation Requirements (Prescriptive) > R402.2.4 Access Hatches and Doors
1011.12.2 Means of Egress, Roof Access
buildings without an occupied roof, access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet (1.5 m 2 ...
Building Code 2015 of Utah > 10 Means of Egress > 1011 Stairways > 1011.12 Stairway to Roof > 1011.12.2 Roof Access
408.3.3 Special Detailed Requirements Based on Use and Occupancy, Guard Tower Doors
A hatch or trap door not less than 16 square feet (610 m 2 ) in area through the floor and having dimensions of not less than 2 feet (610 mm) in any ...
Building Code 2015 of Utah > 4 Special Detailed Requirements Based on Use and Occupancy > 408 Group I-3 > 408.3 Means of Egress > 408.3.3 Guard Tower Doors
1910.23(d)(9) Walking-Working Surfaces,
When a fixed ladder terminates at a hatch (see Figure D-3 of this section), the hatch cover ...
OSHA 1910 General Industry > D Walking-Working Surfaces > 1910.23 Ladders > 1910.23(d) Fixed ladders > 1910.23(d)(9)
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Contact Careers Terms Privacy
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US