• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[F] 913.5 Acceptance Test

Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 913 Fire Pumps > 913.5 Acceptance Test
JUMP TO FULL CODE CHAPTER
Acceptance testing shall be done in accordance with the requirements of NFPA 20.

Related Code Sections


901.5 Fire Protection and Life Safety Systems, Acceptance Tests
Fire protection systems shall be tested in accordance with the requirements of this code and the International Fire Code . Where required ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 901 General > 901.5 Acceptance Tests
909.18 Fire Protection and Life Safety Systems, Acceptance Testing
Devices, equipment, components and sequences shall be individually tested. These tests, in addition to those required by other provisions ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 909 Smoke Control Systems > 909.18 Acceptance Testing
913.5 Fire Protection and Life Safety Systems, Acceptance Test
Acceptance testing shall be done in accordance with the requirements of NFPA 20 ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 913 Fire Pumps > 913.5 Acceptance Test
907.7 Fire Protection and Life Safety Systems, Acceptance Tests and Completion
Upon completion of the installation, the fire alarm system and all fire alarm components shall be tested in accordance with NFPA 72 ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 907 Fire Alarm and Detection Systems > 907.7 Acceptance Tests and Completion
909.18.2 Fire Protection and Life Safety Systems, Ducts
Ducts that are part of a smoke control system shall be traversed using generally accepted practices to determine actual air quantities ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 909 Smoke Control Systems > 909.18 Acceptance Testing > 909.18.2 Ducts
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE