• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.308(a)(1) Aboveground Wiring Methods

OSHA 1910 General Industry > S Electrical > 1910.308 Special Systems > 1910.308(a) Systems Over 600 Volts, Nominal > 1910.308(a)(1) Aboveground Wiring Methods
JUMP TO FULL CODE CHAPTER

1910.308(a)(1)(i)

Aboveground conductors shall be installed in rigid metal conduit, in intermediate metal conduit, in electrical metallic tubing, in rigid nonmetallic conduit, in cable trays, as busways, as cablebus, in other identified raceways, or as open runs of metal-clad cable suitable for the use and purpose. In locations accessible to qualified persons only, open runs of Type MV cables, bare conductors, and bare busbars are also permitted. Busbars shall be either copper or aluminum. Open runs of insulated wires and cables having a bare lead sheath or a braided outer covering shall be supported in a manner designed to prevent physical damage to the braid or sheath.

1910.308(a)(1)(ii)

Conductors emerging from the ground shall be enclosed in approved raceways.

Related Code Sections


1910.308(a)(1) Electrical, Aboveground Wiring Methods
Aboveground conductors shall be installed in rigid metal conduit, in intermediate metal conduit, in electrical metallic tubing, in rigid nonmetallic ...
OSHA 1910 General Industry > S Electrical > 1910.308 Special Systems > 1910.308(a) Systems Over 600 Volts, Nominal > 1910.308(a)(1) Aboveground Wiring Methods
1910.302(b)(3) Electrical, Requirements Applicable Only to Installations Made After April 16, 1981
) -- Swimming pools, fountains, and similar installations -- Fountains ยง 1910.308(a)(1)(ii) -- Systems over 600 volts, nominal -- Aboveground wiring methods ...
OSHA 1910 General Industry > S Electrical > 1910.302 Electric Utilization Systems > 1910.302(b) Extent of Application > 1910.302(b)(3) Requirements Applicable Only to Installations Made After April 16, 1981
1910.305(a) Electrical, Wiring Methods
Only the following wiring methods may be installed in cable tray systems: armored cable ...
OSHA 1910 General Industry > S Electrical > 1910.305 Wiring Methods, Components, and Equipment for General Use > 1910.305(a) Wiring Methods
1910.305(a)(2) Electrical, Temporary Wiring
Except as specifically modified in this paragraph, all other requirements of this subpart for permanent wiring shall also apply to temporary wiring ...
OSHA 1910 General Industry > S Electrical > 1910.305 Wiring Methods, Components, and Equipment for General Use > 1910.305(a) Wiring Methods > 1910.305(a)(2) Temporary Wiring
1910.305(i) Electrical, Fixture Wires
Fixture wires shall be approved for the voltage, temperature, and location of use. A fixture wire which is used as a grounded conductor shall ...
OSHA 1910 General Industry > S Electrical > 1910.305 Wiring Methods, Components, and Equipment for General Use > 1910.305(i) Fixture Wires
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE