Access shall be provided directly from the outdoors to each story below a height of 100 feet (30 480 mm) except to the first story or ground floor, by at least one window or readily identifiable access panel within each 50 feet (15 240 mm) or fraction thereof of horizontal length of every wall that fronts on a street or frontage space. All windows shall be openable from the inside or breakable from both the inside and the outside, and shall have a size when open of at least 24 inches by 36 inches (610 mm by 914 mm). Panels shall be openable from both the inside and outside and shall have a height when open of 48 inches (1219 mm) and a width of at least 32 inches (813 mm). The sill of the window or panel shall not be higher than 36 inches (914 mm) above the inside floor.

Exception: Where not all of the windows are openable or breakable, the windows intended to satisfy the requirements of Section 501.3.2.1 shall be readily identifiable.
Upcodes Diagrams

Related Code Sections

1807.1.1 Soils and Foundations, Story Above Grade
Where a basement or cellar is considered a story above grade and the finished ground level adjacent to the basement or cellar wall is below ...
3202.2 Encroachments Into the Public Right-of-Way, Encroachments Above Grade
Encroachments into the public right-of-way above grade shall be prohibited except as provided for in Sections 3202.2.1 through 3202.2.3 ...
3202.2 Encroachments Into the Public Right-of-Way, Encroachments Above Grade
Encroachments into the public right-of-way above grade shall be prohibited except as provided for in Sections 3202.2.1 through 3202.2.5 ...
3202.2 Encroachments Into the Public Right-of-Way, Encroachments Above Grade
Encroachments into the public right-of-way above grade shall be prohibited except as provided for in Sections 3202.2.1 through 3202.2.3 ...