// DEFINITION
Roofing Accessory
A type of roofing product as described in Section 1517.6 of this code.
Related Code Sections
1517.6 Roof Assemblies and Rooftop Structures, Metal Roofing Accessories
All metal accessories for roofs shall be not less than 26 gage G-90 galvanized or stainless steel, 16 ounce copper, 0.025-inch (0.6 mm) thick ...
1517.6 Roof Assemblies and Rooftop Structures, Metal Roofing Accessories
All metal accessories for roofs shall be not less than 26 gage G-90 galvanized or stainless steel, 16 ounce copper, 0.025-inch (0.6 mm) thick ...
1517.6 Roof Assemblies and Rooftop Structures, Metal Roofing Accessories
All metal accessories for roofs shall be not less than 26 gage G-90 galvanized or stainless steel, 16 ounce copper, 0.025-inch (0.6 mm) thick ...
1517.6.2 Roof Assemblies and Rooftop Structures,
Gravel stops shall be installed after all roofing felts have been ...
1517.6.2.1 Roof Assemblies and Rooftop Structures,
The vertical face shall be a minimum of 11/2 inches (38 mm) and shall extend down not less than 1/2 inch (12.7 mm) below the sheathing or other member ...