// DEFINITION
Primary Sidelighted Area
the total primary sidelighted area is the combined primary sidelighted area within each space. Each primary sidelighted area is directly adjacent to vertical fenestration in an exterior wall below the ceiling (see Figure 3.2-4).
- The primary sidelighted area width is the width of the vertical fenestration plus, on each side, the smaller of
- one half of the vertical fenestration head height (where head height is the distance from the floor to the top of the glazing) or
- the distance to any 5 ft or higher opaque vertical obstruction.
- The primary sidelighted area depth is the horizontal distance perpendicular to the vertical fenestration, which is the smaller of
- one vertical fenestration head height or
- the distance to any 5 ft or higher opaque vertical obstruction.
Related Code Sections
5.9.3.4 Building Envelope, Fenestration Inspections
sidelighted area and secondary sidelighted area below. Roof monitor size and location in relation to the designed primary sidelighted area ...
9.7.3.3 Lighting, Daylighting Documentation
roof monitors, and primary sidelighted area and secondary sidelighted areas ...
5.7.2 Building Envelope, Permit Application Documentation
on the floor plans. Labeling of daylight areas. Daylighting documentation shall identify daylight areas on floor plans, including the primary sidelighted ...
9.4.1.1 Lighting, Interior Lighting Controls
where the combined input power of all general lighting completely or partially within the primary sidelighted areas is 150 W or greater, the general ...
5.5.4.2.3 Building Envelope, Minimum Skylight Fenestration Area
area minus the primary sidelighted area and secondary sidelighted area is less than 2500 ft2 and where the lighting is controlled according ...