504.5 General Site and Building Elements, Nosings
The radius of curvature at the leading edge of the tread shall be 1/2 inch (13 mm) maximum. Nosings that project beyond risers shall have ...
504.5 General Site and Building Elements, Nosings
Nosings shall comply with the following:
Nosings within a stairway shall be uniform.
If rounded, the radius of curvature at the leading edge ...
1029.14.2.4 Means of Egress, Nosing and Profile
Nosing and riser profile shall comply with Sections 1011.5.5 through 1011.5.5.3 ...
1030.14.2.4 Means of Egress, Nosing and Profile
Nosing and riser profile shall comply with Sections 1011.5.5 through 1011.5.5.3 ...
1011.5.5 Means of Egress, Nosing and Riser Profile
Nosings shall have a curvature or bevel of not less than 1/16 inch (1.6 mm) but not more than 9/16 inch (14.3 mm) from the foremost projection ...