// DEFINITION
Embedments, Pipe
—embedded pipes, conduits, and sleeves.
Related Code Sections
20.6 Steel Reinforcement Properties, Durability, & Embedments, Embedments
Reinforcement with an area at least 0.002 times the area of the concrete section shall be provided perpendicular to pipe embedments ...
20.7 Steel Reinforcement Properties, Durability, and Embedments, Embedments
Reinforcement with an area at least 0.002 times the area of the concrete section shall be provided perpendicular to pipe embedments ...
26.8.1 Construction Documents and Inspection,
to be placed perpendicular to pipe embedments.
Specified concrete cover for pipe embedments with their fittings.
Corrosion protection for exposed ...
26.8.1 Construction Documents and Inspection,
to be placed perpendicular to pipe embedments. (c) Specified concrete cover for pipe embedments with their fittings. (d) Corrosion protection ...
20.7.5 Steel Reinforcement Properties, Durability, and Embedments,
Specified concrete cover for pipe embedments with their fittings shall be at least 1-1/2 in. for concrete exposed to earth or weather, and at least 3 ...